[edit] Snotty anon (2002) thought he'd proven that WP was useless. (Where is he now?)
Amazing stuff. How come neither maveric149 nor eclecticology (seemingly busy, high profile editors here) managed not to notice that a micrometer = micrometre = 1/1 000 000 metres, not 1/1000, and that the symbol isn't µ it's µm? Especially since the page micrometre gives the correct info, making it trivial to check the data.
Some reference work this is. --Anon
Yes, it was caught by you - such is the wiki way. There is a million things to do around here and you can't expect any one person to catch them all. --maveric149
But I might reasonably expect the editor of a page to do even the most trival fact-checking while doing that one edit ot that one page, mightn't I? But then you seem to think its a good idea to duplicate the definition of micrometre. Duplication of data encourages errors. Why not just leave the link to micrometre?
- In Wikipedia, there are no editors for a page - everybody is an editor. And since there's so many page, not everybody will read everything. And so there are a lot of errors. But, given enough editors, all of these errors will be found - you just found one, so good job. The reason why there's two different pages is probably because of the measuring device, which is never called a micrometre. Because many Americans may type micrometre when looking for it, there should at least be a reference on this page. And since the article which is to be referred to is so short, it's convenient to included that information here as well. But it is prone to errors, yes. jheijmans
I use "editor" here to mean the person editing a given page at any given time. The history shows that the two users I name above between them created and edited the page into the state it was in when first I saw it. While those acts of editing were going on, the errors were introduced. Since there was a link to the page with the correct info provided, I can only conclude that no effort was put into checking what had been placed on the page, even while knowing that it duplicated info carried on another page. Those users can't claim that this page is one of thousands that they haven't got round to yet, they wrote it in the first place. maveric149 also seems to have taken ownership of the page, undoing the changes to it I made.
While it is a fine idea to expect this resourse to increase in quality through collaborative review, it seems negligent, and an insult to the actual users of a reference work (those who turn to it for information, not the writers of it) to use the expectation of that review as a reason to not bother doing even the simplest, quickest check on new content. As clearly didn't happen in this case.
- I jumped in on this one because I happened to notice that both articles exist, then made the effort to see which was the older so as to apply the generally accepted rule on American vs. British spellings. It's not unusual, Anon, for someone fixing one problem to completely fail to see another. When I do see an obvious error of the type you indicate I find it far more satisfying to fix it than to whine about it. I'm confident that Maveric149 does the same. Try it sometime! -- Eclecticology, Friday, June 7, 2002
- So then, what's your problem. Some editors made a mistake. And the mistake may have easily been prevented. But everybody makes mistakes - you too. And all the other reference works you are using. Maybe not with micrometer, but probably with other entries. And those reference works usually have been read by several editors to check for errors - so does this one. Only, everything is directly available to the public, so errors may remain until they are correct. As a user of Wikipedia, you have to know that. If you can't live with it, don't use Wikipedia. But if you want to use it and if you find such an error, point it out or - even beter - correct it. That's what this project is about. And if the error made seems to be made on purpose, you can point that out, and discuss it with the editors. But a simple error such as this doesn't deserve this much talking. It just happens. jheijmans
[edit] Article structure (fixed since)
- is it me or does this article just seem to be structured like a block? I think it could do with some thinning out to make it less of a mountain to find what you're after.. I struggled to skim read the article I was merely looking for 1 cross reference.
[edit] Figure 3?
Which figure is Figure 3? —The preceding unsigned comment was added by Mikeblas (talk • contribs) .
- Thanks for the heads up, the images had been deleted according to policy. I've uploaded replacements and adjusted the text to suit, hopefully no errors crept in. — Graibeard 09:10, 14 January 2006 (UTC)
- Thanks for the fix! I linked to vernier scale, and clarified about inch-metric. -- Mikeblas 17:18, 14 January 2006 (UTC)
[edit] Requests
Larger outside micrometers don't close the whole way, and are supplied with calibration sticks. How are the calibration sticks used? The article also doesn't describe the ratcheting thimble found on many micrometers. (In fact, it doesn't define "thimble" and "barrel" before using the terms.). -- Mikeblas 17:21, 14 January 2006 (UTC)
Addendum: The "sticks" you are referring to are called micrometer standards. They are calibrated to a specific length and are used to ensure that micrometers are accurate. They are used by measuring them with the micrometer, and then setting the micrometer. For instance, if you are using a 6" standard to check a 6"-7" micrometer, you would tighten the micrometer on the ends of the standard to where you can just feel a little dra, then adjust the micrometer so it reads 6.00" [(user: dad7892]) 15:25 16 July 2006 (UTC)
[edit] Calibration
How is a micrometer calibrated? —The preceding unsigned comment was added by 63.193.73.194 (talk) 22:06, 11 December 2006 (UTC).
Article could explain, if true, that calibration includes adjusting the micrometer so there is no zero error. Outside micrometers come with a small wrench - presumably used to twist the sleeve to eliminate the zero error ? Would a user normally do this themselves or leave it to a formal calibration ? - Rod57 (talk) 12:15, 4 August 2011 (UTC)
- Found this Calibration procedure for calibration of External micrometer detailed. Concentrates more on condition of the tips and linearity of the scale.
- ITTC – Recommended Procedures : Sample Work Instructions Calibration of Micrometers 12 pages of explanation and diagrams. Wonderful, I'll add it to external links. - Rod57 (talk) 12:32, 4 August 2011 (UTC)
[edit] what is the principle of micrometer's measuring and reading techinques
when we read the measured value, normally we have to check the value on thimble which coincides with the axial line on the sleeve which will be added to the value gotten from the sleeve to deduce final result. Why do we do that, what is the principle associated? hope some one can clarify it —The preceding unsigned comment was added by Panda cool (talk • contribs) 13:56, 9 March 2007 (UTC).
- I hope my creation tonight of the "Operating principles" section helps out. The answer to your question is easy to understand once understood, just difficult to describe in words! Imagine the following example: You are using a typical "regular" micrometer (outside micrometer caliper, 0"-1" range). You are going to start from zero and "unscrew" the micrometer to something a bit less than 1/8"—Let's say .123 instead of perfect 1/8 (.125). Now, starting from zero, it takes four turns of the thimble to cover the first hundred thousandths (.100). That reveals the first 4 hash marks on the barrel, which you duly note. The final 23 thousandths (.023) is less than one turn of the thimble. You read the marks on the thimble to see how much of that final (5th) turn you get before getting to your "destination". It is 23 out of 25. This thought experiment shows why when you read a micrometer, you start by reading the linear scale on the barrel, then you finish by read that final, partial turn of the thimble. Hope that helps! — ¾-10 00:34, 14 November 2007 (UTC)
[edit] Advantages
The opening paragraph states that a micrometer has "several advantages" over other measuring devices like calipers, but this is never discussed in the article. What are the advantages? Julesd 13:19, 19 October 2007 (UTC)
- This is an interesting question. A mic is less annoying to read than a vernier caliper, and *may* be more accurate than a dial caliper. But if you're comparing a good, high-quality, name-brand version of each (mic and dial caliper), they are both spot-on and can be trusted to inside of one thou. One advantage of the mic is that it may have a vernier scale to read that last ten-thousandth, which the dial caliper doesn't have. But you know, for practical purposes, given high-quality specimens that have been calibrated not too long ago, I think the mic may not have anything on the dial caliper as far as shop-floor pros and cons go. But psychologically the mic is the one that conventional wisdom trusts to be "superior". — ¾-10 00:47, 14 November 2007 (UTC)
-
- I used to teach precision measuring at the College I work at. They still use the course I created that automated practical as well as theoretical assessment in the course. It has fully interactive flash based lessons as well as randomly generated quizzes from test banks with thousands of questions. It is easily demonstrated statistically in the more than 37,500 graded practical measurements we perform in our program every year that the micrometer requires far less skill to achieve accuracy +-.0005" or .00005 depending on whether the mic has a .0001" scale on the barrel or not. Sliding calipers in practical assessment in our program have been shown to only achieve a +-.001" repeatability with the average student. IE: if we tighten up the parameters to grade actual measuring projects within .0005", very few students are successful with sliding calipers as opposed to micrometers. I use dial calipers for most measurement, but when I need to do something within .0005", let alone .00005" it's always a mic. (Njmorin (talk) 12:53, 18 December 2009 (UTC))
- Thanks for adding this info. Glad that someone could bring some hard data to the question. I think you summed it up perfectly in that dial calipers are good enough for many applications, and that when you need to be down inside the last thou, checking the tenths with certainty, then a mic is needed. — ¾-10 00:07, 19 December 2009 (UTC)
- I used to teach precision measuring at the College I work at. They still use the course I created that automated practical as well as theoretical assessment in the course. It has fully interactive flash based lessons as well as randomly generated quizzes from test banks with thousands of questions. It is easily demonstrated statistically in the more than 37,500 graded practical measurements we perform in our program every year that the micrometer requires far less skill to achieve accuracy +-.0005" or .00005 depending on whether the mic has a .0001" scale on the barrel or not. Sliding calipers in practical assessment in our program have been shown to only achieve a +-.001" repeatability with the average student. IE: if we tighten up the parameters to grade actual measuring projects within .0005", very few students are successful with sliding calipers as opposed to micrometers. I use dial calipers for most measurement, but when I need to do something within .0005", let alone .00005" it's always a mic. (Njmorin (talk) 12:53, 18 December 2009 (UTC))
[edit] Parts and Functions
What are they ? —Preceding unsigned comment added by 222.127.62.62 (talk) 04:48, 13 November 2007 (UTC)
- I just filled in this info under a new section, "Parts", with a labeled image. — ¾-10 22:57, 13 November 2007 (UTC)
[edit] Instructions vs Description
The sections on reading a micrometer are all fairly similar, but only the last one has the {{howto}} tag. I'm adjusting the phrasing of the content a bit to make it more descriptive of how the system of graduations work and less of an instruction manual.
Pstemari (talk) 16:25, 20 April 2008 (UTC)
[edit] Tube Micrometers
Please add diagrams and text detailing Tube Micrometers. -69.87.204.208 (talk) 12:24, 13 May 2008 (UTC)
[edit] Large Outside micrometers
Larger Outside micrometers do not close to zero. This is quite an important detail. Please add a picture and text highlighting this aspect, and informing about the terms used to distinguish micrometers that do or do not close to zero. -69.87.204.208 (talk) 12:24, 13 May 2008 (UTC)
- I found at Google Book Search one of those great old images of a very large micrometer caliper in use. It is public domain because of age. I created a gallery section to put it in. The resolution is poor, which will probably attract the kind of flies that would rather delete useful images than have them be tolerably low-res, but there isn't much you can do for that kind of fly-brain except revert the deletion. For the rest of us with normal brains, the image is useful and interesting. Cheers, — ¾-10 16:13, 11 April 2009 (UTC)
[edit] History
Please add pictures, diagrams, and more details to the history section. -69.87.204.208 (talk) 12:24, 13 May 2008 (UTC)
[edit] astronomy
What is the use of the micrometer in astronomy? This article makes no mention of it, though several articles which link here are about astronomical uses of the device. -- Mikeblas (talk) 15:36, 9 July 2008 (UTC)
- It is mentioned briefly under section Micrometer#History of the device and its name. Could use more detail if anyone can supply. — ¾-10 02:42, 31 December 2008 (UTC)
[edit] Microbes
What is the proceedure of mesuring microbes in simplified form? Detail would be apreciated
- Uh, I think you got the wrong article. Plus you should read WP:NOTHOWTO. Try the reference desk. Wizard191 (talk) 12:43, 31 August 2010 (UTC)
[edit] Materials
how are micrometers classified based on the metal with which they are made of ? or what are common metals used in the manufacture of micrometers?
nice content.. thanks..
- I'm not aware of any classification systems based on the type of material they are made from. Wizard191 (talk) 20:23, 27 April 2011 (UTC)
-
- Me neither. Materials commonly used in their making include tool steel, stainless steel, cast iron, die-cast alloys, sometimes plastics (no idea what type, chemically). Covered by plating and baked enamel paint in some cases. Metal frames sometimes have plastic guards over them to insulate the frame from the body heat of the hand holding it. HTH. — ¾-10 22:36, 27 April 2011 (UTC)
-
-
-
- My understanding is that they're body heat insulators. But I don't remember where I first learned that, or if it's certifiably true. Now that I look, the article already mentions this insulation idea (I had thought it didn't). I have to admit I always thought the insulation idea was kind of silly or overblown, like "how much can my hand really affect the measurement? It's only 37.0 °C (98.6 °F)". And many mics, even top-notch brands, don't come with them, so that suggests to me that it's overblown. But I guess maybe it's true that it could mean a few microns. Still, I guess I'll never believe that the effect matters for practical purposes (mfg) unless someone shoves a science experiment in front of me proving that it does! — ¾-10 21:50, 28 April 2011 (UTC)
-
-
-
-
-
-
- BTW, re "radiation" versus "light", I had to be a nerd and point out that light is included in electromagnetic radiation. But you're totally right that "light" is the right word to use here, and "radiation" is a poor choice because it evokes Chernobyl/Fukushima in the average reader's mind upon first sight. Whereas "light" is more specific and also plainer/clearer at the same time. So speaking of calibration, thanks for calibrating on "nerd-speak vs le mot juste". — ¾-10 01:32, 29 April 2011 (UTC)
-
-
-
[edit] Need more textual explanation of "zero error" method
Prof Lookang, can you write a sentence or two explaining what is meant by "zero error"? The term sounds like it is referring to the mic's accuracy and precision or its calibration, but I infer that it actually refers to a certain method of dialing the barrel. I watched the animation but didn't have time to deeply ponder it. What I'd like to do is to describe in words what "zero error" is referring to, in addition to the animation. Thanks for any help, — ¾-10 01:27, 21 July 2011 (UTC)
- Ah, thank you, Prof Lookang! Your recent explanation is helpful. Basically you are talking about applying a correction factor to a mic that's known to be out of calibration. Kind of like subtracting a tare weight value from the reading on a weighing scale that's out of calibration. Or subtracting the starting volume of a solution from the ending volume to find the change. Thanks for explaining. — ¾-10 21:40, 21 July 2011 (UTC)
glad to see it is well received by Wikipedia community! (Lookang (talk) 15:14, 13 August 2011 (UTC)).
[edit] External Links
I am wondering why we cannot add this as external links http://www.phy.ntnu.edu.tw/ntnujava/htmltag.php?code=users.sgeducation.lookang.Micrometer01_pkg.Micrometer01Applet.class&name=Micrometer01&muid=14019 it is an interactive java applet simulation, full screen, clear, useful to many teachers and students and the public, created by physics professor Fu-Kwun Hwang and teacher lookang. :) (Lookang (talk) 15:18, 13 August 2011 (UTC)).
- I agree. People keep removing it citing WP:ELNO, but that is because they are mistaking it for self-promotion or advertisement. I think it should stay, personally. If others disagree then please prove me wrong here at talk rather than just keep deleting it. Thanks. — ¾-10 18:48, 13 August 2011 (UTC)