Low-frequency electromagnetic compatibility

From Wikipedia, the free encyclopedia

This is an old revision of this page, as edited by ShelfSkewed (talk | contribs) at 04:38, 7 November 2022 (→‎Directions of development: dab link). The present address (URL) is a permanent link to this revision, which may differ significantly from the current revision.

Frequency spectrum of harmonic pollution

Low frequency electromagnetic compatibility (LF EMC) is a specific field in the domain of electromagnetic compatibility (EMC) and power quality (PQ), that deals with electromagnetic interference phenomena in the frequency range between 2 kHz and 150 kHz. It is a special frequency range, because it does not fit in the PQ problems,[1] with range of up to 2 kHz (3 kHz in 60 Hz mains frequency systems, such as the United States), where relative levels of voltage and current can have massive impact on efficiency and integrity of electric systems, and neither in the conducted EMC range, which starts at 150 kHz and influences mainly informational systems, and already too far from radiated EMC range, which starts at 30 MHz and goes up to 1 GHz. This is a newer field of interest in PQ and EMC, stated by the fact that the professional community has not reached a consensus on terminology[citation needed], LF EMC harmonics being called supraharmonics.,[2] and another fact being a void in standards considering the LF EMC frequency range.[2]

Causes

Generation of LF EMC harmonics due to smart grid

The main cause for the appeareance of low frequency electromagnetic interferences in home and industrial electric systems is the dense integration of power electronics switching frequency.[2] In time, switching power devices, such as transistors, became cheap, small and easy to use, invading all facets of human activity. The switching frequency of these devices got beyond 2 kHz and their power bearing capabilities grew to the point at which they started controlling electric devices, such as electric motors, that are more power hungry.[3]

Another rising cause for 2 kHz - 150 kHz disturbances in electric power systems is the continuous integration of renewable energy sources and the evolution of the power system to smart grid. The smart grid, at basis, uses ICT systems to control power inlets and outlets via power converters, meaning a heavy use of switching devices within the LF EMC range.[4]

Effect

The ratio of harmonic weight to the fundamental frequency in the LF EMC range also grew, leading to increased harmonic pollution, which disturbs the quality of power delivered to consumers, and disturbances to the informational and telecommunication systems nearby. The impact of the LF EMC was determined to have serious effects on all electrical connections and devices. The diagnosis of supraharmonics-related problems based on the effects on electrical equipment was researched by Sakar et al.[4] The propagation of LF harmonics through LV and MV grids leads to interference with the elements for power delivery and end-user equipment, e.g., light flicker, aging of capacitors and cable terminations, audible noise and interruption of electric vehicle charging. As such incidents happen more often, the need for guidelines that facilitate the diagnosis of these problems arises. Different features of the LF distortion were shown to be responsible for different interferences.[4] These problems were organized in problem specific flow charts for audible noise, cable terminations failure, unwanted tripping due to residual current devices, and flicker.[4] On power converters, the LF harmonics were shown to generate in turn a series of EMC pollution problems. Interharmonics are one of the heaviest polluters in this interaction.[5] Though the study was done on LED converters and low voltages, the impact on high voltage applications such as railway traction can have an amplified detrimental effect.[5]

Directions of development

There are a lot of challenges to be considered in this relatively new field. A series of studies have already been published, but the professional community still has not solved some very important challenges in the low frequency domain of EMC and PQ. The Institute of Electrical and Electronics Engineers has already formed a technical committee to work on these issues, starting with the standardization issues.[6]

Standards

PQ, EMC and LF EMC standarts coverage

The standardization issue with the frequency of 2 – 150 kHz is dual: on the one hand there are no specific and agreed upon standards that mandate the designers of electric systems to account for this range, and on the other hand there are no standards that would guide the measurement of EMI in this specific frequency range. There are standards that cover the PQ area, and EMC area, but in between there is a significant gap, that spurs issues with every new electric system or device.[8]

See also

Conducted emissions

Electric power quality

Power factor

References

  1. ^ Rönnberg, S. K. (2017). "On waveform distortion in the frequency range of 2 kHz–150 kHz—Review and research challenges". Electric Power Systems Research. 150: 1–10. doi:10.1016/j.epsr.2017.04.032.
  2. ^ a b c Jan Meyer; Victor Khokhlov; Matthias Klatt; Juergen Blum; Christian Waniek; Thomas Wohlfahrt; Johanna Myrzik (2018). "Overview and Classification of Interferences in the Frequency Range 2–150 kHz (Supraharmonics)". IEEE Xplore. doi:10.1109/SPEEDAM.2018.8445344. Wikidata Q112827311.
  3. ^ Millán, J. (May 2014). "A Survey of Wide Bandgap Power Semiconductor Devices". IEEE Transactions on Power Electronics. 29 (5): 2155–2163. Bibcode:2014ITPE...29.2155M. doi:10.1109/TPEL.2013.2268900. S2CID 23719999.
  4. ^ a b c d S. Sakar; S. K. Rönnberg; M. Bollen (July 2021). "Interharmonic Emission in AC–DC Converters Exposed to Nonsynchronized High-Frequency Voltage Above 2 kHz". IEEE Transactions on Power Electronics. 36 (7): 7705–7715. doi:10.1109/TPEL.2020.3047862. ISSN 0885-8993. Wikidata Q112827082.
  5. ^ a b Ángela Espín-Delgado; Sarah Rönnberg; Shimi Sudha Letha; Math Bollen (June 2021). "Diagnosis of supraharmonics-related problems based on the effects on electrical equipment". Electric Power Systems Research. 195 (4). doi:10.1016/J.EPSR.2021.107179. ISSN 0378-7796. Wikidata Q112827201.
  6. ^ "TC7 Low Frequency EMC". TC 7 Low Frequency EMC.
  7. ^ Wan, Lu (2021). "Limitations in Applying the Existing LISN Topologies for Low Frequency Conducted Emission Measurements and Possible Solution". 2021 Asia-Pacific International Symposium on Electromagnetic Compatibility (APEMC): 1–4. doi:10.1109/APEMC49932.2021.9596980. hdl:11311/1199963. ISBN 978-1-7281-7621-5. S2CID 244274225.
  8. ^ Alkahtani, Ammar Ahmed (2020). "Power Quality in Microgrids Including Supraharmonics: Issues, Standards, and Mitigations". IEEE Access. 8: 127104–127122. doi:10.1109/ACCESS.2020.3008042. S2CID 220733743.

External links