Jump to content

Schering bridge

From Wikipedia, the free encyclopedia

This is the current revision of this page, as edited by Chongkian (talk | contribs) at 02:27, 26 November 2021 (leave two blank lines between the first stub template and whatever precedes it per WP:STUBSPACING). The present address (URL) is a permanent link to this version.

(diff) ← Previous revision | Latest revision (diff) | Newer revision → (diff)

The Schering bridge is an electrical circuit used for measuring the insulating properties of electrical cables and equipment.[1] It is an AC bridge circuit, developed by Harald Schering. It has the advantage that the balance equation is independent of frequency.

The connections of the Schering bridge under balance conditions are shown in the figure below.

Schering bridge diagram

In this diagram:

  • C1 = capacitor whose capacitance is to be determined,
  • R1 = a series resistance representing the loss in the capacitor C1,
  • C2 = a standard capacitor,
  • R3 = a variable non-inductive resistance,
  • C4 = a variable capacitor,
  • R4 = a non-inductive resistance in parallel with the variable capacitor C4.


References

[edit]
  1. ^ Schering Bridge (Measurement of Capacitance), Myclassbook, 2 August 2013