Jump to content

Membrane oxygenator: Difference between revisions

From Wikipedia, the free encyclopedia
Content deleted Content added
→‎History: contextualize
→‎History: Expanded and corrected: much early work was published directly, without regard to intellectual property, hence patent filing does not reflect the true history of these discoveries.
Line 2: Line 2:


==History==
==History==

The artificial oxygenation of blood traces back to the late nineteenth century. The first U.S. patent for a membrane oxygenator was filed in 1957 by [[John Julian Wild]] and H.W. Heupel.<ref>[http://www.google.com/patents?vid=USPAT3070092&id=I1xwAAAAEBAJ&printsec=abstract&zoom=4&dq=membrane+oxygenator+wad#PPP5,M1|U.S. Patent 3,070,092] </ref> Another variety of membrane oxygenator is the Peirce-General Electric membrane oxygenator, developed in the 1960s by [[E. Converse Peirce 2nd]]. {{Fact|date=February 2007}}
The history of the oxygenator, or artificial lung, dates back to 1885, with the first demonstration of a disc oxygenator, on which blood was exposed to the atmosphere on rotating discs by Von Frey and Gruber [Dorson and Loria, 1988]. These pioneers noted the dangers of blood streaming, foaming and clotting. In the 1920s and 30s, research into developing extracorporeal oxygenation continued. Working independently, Brukhonenko in the USSR and Gibbon in the USA demonstrated the feasibility of extracorporeal oxygenation. Brukhonenko used excised dog lungs while Gibbon used a direct contact drum type oxygenator, perfusing cats for up to 25 minutes in the 1930s [Galletti, 1993].
Gibbon’s pioneering work was rewarded in May 1953 with the first successful cardiopulmonary bypass operation [Gibbon, 1955]. The oxygenator was of the stationary film type, in which oxygen was exposed to a film of blood as it flowed over a series of stainless steel plates.
The disadvantages of direct contact between the blood and air were well recognised, and the less traumatic membrane oxygenator was developed to overcome these. The first membrane artificial lung was demonstrated in 1955 [Kolff and Balzer, 1955], and in 1956 the first disposable membrane oxygenator removed the need for time consuming cleaning before re-use [Kolff and Effler, 1956]. No patent was filed as Kolff believed that doctors should make technology available to all, without mind to profit [Kolff, citation needed]. The early artificial lungs used relatively impermeable polyethylene or Teflon® homogeneous membranes, and it was not until more highly permeable silicone rubber membranes were introduced in the 1960s (and as hollow fibres in 1971) that the membrane oxygenator became commercially successful [Kolobow and Bowman, 1963, Dutton ''et al''., 1971]. The introduction of microporous hollow fibres with very low resistance to mass transfer revolutionised design of membrane modules, as the limiting factor to oxygenator performance became the blood resistance [Gaylor, 1988]. Current designs of oxygenator typically use an extraluminal flow regime, where the blood flows outside the gas filled hollow fibres, for short term life support, while only the homogeneous membranes are approved for long term use.


==See also==
==See also==

Revision as of 03:40, 12 November 2007

A membrane oyxgenator imitates the function of the lungs in cardiopulmonary bypass (CPB). A membrane oxygenator consists of a thin membrane separating the blood and gas flows in the CPB circuit; oxygen diffuses from the gas side into the blood, and carbon dioxide diffuses from the blood into the gas for disposal.

History

The history of the oxygenator, or artificial lung, dates back to 1885, with the first demonstration of a disc oxygenator, on which blood was exposed to the atmosphere on rotating discs by Von Frey and Gruber [Dorson and Loria, 1988]. These pioneers noted the dangers of blood streaming, foaming and clotting. In the 1920s and 30s, research into developing extracorporeal oxygenation continued. Working independently, Brukhonenko in the USSR and Gibbon in the USA demonstrated the feasibility of extracorporeal oxygenation. Brukhonenko used excised dog lungs while Gibbon used a direct contact drum type oxygenator, perfusing cats for up to 25 minutes in the 1930s [Galletti, 1993]. Gibbon’s pioneering work was rewarded in May 1953 with the first successful cardiopulmonary bypass operation [Gibbon, 1955]. The oxygenator was of the stationary film type, in which oxygen was exposed to a film of blood as it flowed over a series of stainless steel plates. The disadvantages of direct contact between the blood and air were well recognised, and the less traumatic membrane oxygenator was developed to overcome these. The first membrane artificial lung was demonstrated in 1955 [Kolff and Balzer, 1955], and in 1956 the first disposable membrane oxygenator removed the need for time consuming cleaning before re-use [Kolff and Effler, 1956]. No patent was filed as Kolff believed that doctors should make technology available to all, without mind to profit [Kolff, citation needed]. The early artificial lungs used relatively impermeable polyethylene or Teflon® homogeneous membranes, and it was not until more highly permeable silicone rubber membranes were introduced in the 1960s (and as hollow fibres in 1971) that the membrane oxygenator became commercially successful [Kolobow and Bowman, 1963, Dutton et al., 1971]. The introduction of microporous hollow fibres with very low resistance to mass transfer revolutionised design of membrane modules, as the limiting factor to oxygenator performance became the blood resistance [Gaylor, 1988]. Current designs of oxygenator typically use an extraluminal flow regime, where the blood flows outside the gas filled hollow fibres, for short term life support, while only the homogeneous membranes are approved for long term use.

See also

References

Oxygenator summary in Cardiac Surgery in the Adult