= Analysis = |
= Analysis = |
||
==Mathematical Error== |
|||
First, I will explain all of our error estimates. We used propagation of errors, ie, for any variable <math>X<math> (like Intensity <math>I<math> or mean distance <math>d<math>), |
|||
:<math>(err_X/X)^2 = \sum (err_i / q_i)^2</math> |
|||
where <math>q_i</math> is the ith components of <math>err_X<math>. The error is either recorded as 0.5 the smallest seeable tick mark for collected data, or error is found using propagation of variables. |
|||
==Human Error== |
|||
Hopefully, systematic error is noted and corrected for (like the variable $noise$ which is our measurement of how the room light affected current readings), or accrued into the error bars (measurement error and propagated error). However, due to imperfect alignment, and other things that may not be idea (for instance, our camera lens was not the given focal length away from the photodiode, and the light beam hitting the face-on photodiode was slightly angled) we have human-made error inherent in the data. |
|||
==Data== |
|||
* lambda is the wavelength in nm |
|||
* d1, d2, and d are all measurements on the translational stage micrometer focus (mm) |
|||
* c1, c2, and c are peak current measurements (uA) |
|||
* FWHM is the FWHM of the transmittance from the filter |
|||
* peak is the peak % of the filter |
|||
* noise is a measurement of how outside light changes our measurements |
|||
* R is the responsivity from the lab handout |
|||
* QE is calculated quantum efficiency |
|||
* SR is steradians of light (sr) |
|||
* I is intensity (kW m-2 sr-1 nm-1) |
|||
* angle is the angle of rotation (deg) |
|||
recall |
|||
:<math>r_{beam} = 1.1 +/- 0.05 cm</math> |
|||
:<math>R_{guess} = 110 cm</math> |
|||
Intensity equation |
|||
:<math>I = (c / R) * (peak/FWHM^2) / (SR * lambda)</math> |
|||
To get the m^-2 dependence in the intensity, divide the current by an approximation to the transmittance there, which is peak/FWHM^2. noise is consistantly <1% of the current measurements and pretty stable; we will fold it into our equation. SR is more complicated. I didn't measure the distance from the light source to the photodiode, so SR is a guess. Because of this, I did not fold in the error from this, as it would be on order of 20cm/20% of the value. |
|||
:<math>SR = A/R^2 = pi * (r_{beam}/R)^2 = 3.801 * R_{guess}^{-2} = pi * 10^{-4}</math> |
|||
Note, error of the intensity is calculated by propagation of errors of four elements (current, peak, R, FWHM, but not SR) and still ends up at almost 10%. With the SR error included, this rises to 25%-93% of each intensity point (see err_I with SR column). |
Revision as of 16:58, 16 January 2015
This lab will teach us basics of optics: using the optical bench, 3D optical alignment and dealing with rotation of elements, stray light control, and treating equipment well. We want to examine the blackbody spectrum of the lamp. We will use refraction in a collimating lens to collimate the light beam and refocus it on a small ccd. We'll examine the blackbody spectrum dependence on wavelength and angle.
Equipment
Part A
These are the steps for alignment of the optics we will use. For background and more details about the equipment, see the lab handout.
1. Attached rail to table aligned with translational stage.
2. Mounted photodiode assembly on translational stage and set micrometer to the midpoint of the focus travel
3. Attached camera lens *#32974 plano convex lens with 50mm diameter and 150mm focal length). Best optical performance when the convex side of the lens is facing the lamp and the flat side of the lens is facing the detector. Careful: both filters and lenses should only be touched on the edge, away from the path of the incoming beam.
Q. How far from the photodiode does this camera lens belong?
A. Approximately 150mm.
4. Attached empty filter holder
5. Attached iris and taped paper to block extra incoming light
6. Collimating lens (#31402 achromate with 63 mm diameter and 356mm focal length). The curvier surface faces the iris.
7. QTH lamp #63200. Mounted approximately 350mm from the collimating lens. We did not plug the power supply in and made sure the toggle on the back was turned to off. Then we took black/white wires from the lamp and connected the leads to the lugs on the power supply. Finally we plugged in the power supply and turned it on.
8. Collimating part i! We first took off the optical elements after the iris so we can check the size of beam on the wall relative to the size of the iris. The circle on the wall is 4.5cm at first. The one after the iris was about 4cm. We checked that the lens is exactly on axis. The y axis (of the beam on the wall) was aligned by first trying to maximize the size of the beam on the wall (rotated collimating lens leads to oblique circles) and also checking from the top. Then we aligned the source of the light, the lamp, with the optical array. After, we aligned the lens in the y and the z axis so the beam was centered on the iris.
9. Collimating part ii! We rechecked the beam size after the iris. The iris is 4.10 +/- 0.05 cm, and we got the beam on the wall, which was about a meter away, to the same size.
10. The filter was approximately aligned in the z/height direction, and the camera lens was put at the focal length away from the camera (checked). We also checked the angle of the planoconvex lens. We closed the iris a little so the filter holder would not get in the way.
11. The lamp was a bit low, so it means our z axis alignment is off. We realigned everything. We raised the lamp, centered it with the iris, knew our beam was collimated, and realigned the z axis of all the other pieces. Luckily, we were able to keep the beam collimated (we checked the beam diameter).
12. The camera lens ended up being 9 +- 0.5 cm from the photodiode.
13. Attached BNC coax cable from photodiode to the input terminal of the high dynamic range transimpedance amplifier, turned it on after plugging it all together.
14. Adjusted current range to the smallest non-(-1) reading for best precision. This was 200 microamps, so our unit is uA. This works, so we have a final iris diameter to 2.15 +/- 0.05 cm (measured twice).
Q. What is the reimaged size of the QTH filament on the diode?
A. We measured 1mm +- 0.5 diameter, so area < 1mm^2 which is the size of the photodetector.
15. Take measurements.
Part B
16. We removed the lens hlder and the camera lens. We removed the translational stage and replaced it with the rotational stage. We put the photodiode assembly back on the rotation axis, by using the post holder that can screw into the rotational stage, and being careful with the posts that are now a bit too small.
17. Alignment was easy this time. Do the same as yesterday, but because we do not need to move our setup much, only corrections were made.
18. Take measurements. See section 3B.
Measurements
Part A
Make two measurements (ie, multiple times of each):
- translational stage micrometer focus reading
- value of maximum current
We made the 400nm measurements and then stopped for the next day.
(Day 2)
We continued with the Part A Measurements.
1. Pick a filter (600nm). Record the current as a function of micrometer focus reading using stems of 0.5mm over a focus range of +/- 2.5mm from best focus.
2. We ran measurements to the low end, repeated the center one, and did two measurements of each.
Part B
1. We measured in steps of 5deg the current as a function of angle.
Q. You can determine how accurately you were aligned at the center position by comparing measurements at +- a few steps, why?
A. Because the maximum current implies the beam was orthoganal to the ccd.
Tables
Table 1A: Column definitions and error
col | name | err | units | explanation |
lambda | wavelength | nm | ||
d1 | distance | 0.005 | mm | translational stage micrometer focus reading |
d2 | distance | 0.005 | mm | translational stage micrometer focus reading |
c1 | current | 0.0005 | uA | value of maximum current |
c2 | current | 0.0005 | uA | value of maximum current |
FWHM | FWHM | 0.5 | nm | filter FWHM |
peak | peak | 0.5 | % | filter peak value |
noise | noise | 0.0005 | uA | outside light |
R | reponsivity | 0.0025 | A/W | diode efficiency, to help get QE |
QE | unitless quantum efficiency QE = R* 1.24e-6 / lambda | |||
d | distance | 0.007 | mm | mean(d1, d2) |
c | current | 0.0007 | uA | mean(c1, c2) |
I() | intensity | varies | kW m-2 sr-1 nm-1 | Intensity of QTH lamp |
Table 1B: Current := f(lambda, distance)
lambda | d1 | d2 | c1 | c2 | FWHM | peak | noise | R | QE |
400 | 11.22 | 10.245 | 0.105 | 0.108 | 70 | 65 | 0.087 | 0.2697 | |
450 | 11.479 | 11.475 | 0.381 | 0.386 | 70 | 74 | 0.005 | 0.162 | 0.4464 |
500 | 11.462 | 11.369 | 0.671 | 0.669 | 69 | 73 | 0.003 | 0.232 | 0.57536 |
550 | 12.012 | 12.071 | 1.063 | 1.064 | 68 | 74 | 0.004 | 0.295 | 0.6650909091 |
600 | 12.662 | 12.155 | 1.706 | 1.703 | 64 | 74 | 0.006 | 0.354 | 0.7316 |
650 | 13.242 | 13.211 | 2.09 | 2.1 | 70 | 72 | 0 | 0.406 | 0.7745230769 |
700 | 13.355 | 13.726 | 3.19 | 3.2 | 77 | 67 | 0 | 0.451 | 0.7989142857 |
Table 1C: Intensity
lambda | d | c | err_d | err_c | I | err_I | err_I with SR |
400 | 10.7325 | 0.1065 | 0.007092993139 | 0.0007073172262 | 1.292262008 | 0.1161014856 | 0.2620767432 |
450 | 11.477 | 0.3835 | 0.007071068134 | 0.0007071518569 | 2.528927713 | 0.2179880049 | 0.5088609278 |
500 | 11.4155 | 0.67 | 0.007071243806 | 0.000707109144 | 2.819060706 | 0.2426771338 | 0.5671034727 |
550 | 12.0415 | 1.0635 | 0.007071131471 | 0.0007071070156 | 3.339101487 | 0.2886122669 | 0.6722193223 |
600 | 12.4085 | 1.7045 | 0.007075496344 | 0.0007071076026 | 4.615058398 | 0.4104081881 | 0.9340911376 |
650 | 13.2265 | 2.095 | 0.007071082378 | 0.0007071128228 | 3.713162788 | 0.3157086576 | 0.7452916579 |
700 | 13.5405 | 3.195 | 0.007073058803 | 0.0007071093788 | 3.64042903 | 0.2953008377 | 0.7247821379 |
Table 2A: Column definitions and error
d | distance | 0.005 | mm | translational stage micrometer focus reading |
c1 | current | 0.0005 | uA | value of maximum current |
c2 | current | 0.0005 | uA | value of maximum current |
c | current | 0.0007 | uA | mean(c1, c2) |
Table 2B: Current := f(600nm, distance)
d | c1 | c2 | c | err_c |
9.46 | 1.444 | 1.443 | 1.4435 | 0.0007071069084 |
9.96 | 1.539 | 1.593 | 1.566 | 0.0007074221644 |
10.46 | 1.616 | 1.618 | 1.617 | 0.0007071071868 |
10.96 | 1.69 | 1.673 | 1.6815 | 0.000707133885 |
11.46 | 1.72 | 1.714 | 1.717 | 0.0007071100192 |
11.96 | 1.803 | 1.79 | 1.7965 | 0.0007071206664 |
12.46 | 1.75 | 1.807 | 1.7785 | 0.0007073792147 |
12.96 | 1.74 | 1.798 | 1.769 | 0.0007073918985 |
13.46 | 1.724 | 1.765 | 1.7445 | 0.0007072532675 |
13.96 | 1.671 | 1.721 | 1.696 | 0.0007073372919 |
14.46 | 1.617 | 1.659 | 1.638 | 0.0007072811434 |
Table 3A: Column definitions and error
angle | angle | 0.5 | deg | rotational stage angle reading |
c1 | current | 0.0005 | uA | value of maximum current |
c2 | current | 0.0005 | uA | value of maximum current |
c | current | 0.0007 | uA | mean(c1, c2) |
Table 3B: Current := f(white light, angle)
angle | c1 | c2 | c | err_c |
0 | 0.011 | 0.011 | 0.022 | 0.0007 |
5 | 0.011 | 0.011 | 0.027 | 0.0007 |
10 | 0.016 | 0.016 | 0.055 | 0.0007 |
15 | 0.039 | 0.039 | 0.141 | 0.0007 |
20 | 0.102 | 0.102 | 0.2855 | 0.0007 |
25 | 0.184 | 0.183 | 0.4055 | 0.0007 |
30 | 0.222 | 0.222 | 0.4655 | 0.0007 |
35 | 0.244 | 0.243 | 0.568 | 0.0007 |
40 | 0.326 | 0.323 | 0.801 | 0.0007 |
45 | 0.477 | 0.476 | 1.1455 | 0.0007 |
50 | 0.668 | 0.67 | 1.502 | 0.0007 |
55 | 0.834 | 0.832 | 1.761 | 0.0007 |
60 | 0.931 | 0.925 | 1.9615 | 0.0007 |
65 | 1.034 | 1.033 | 2.1695 | 0.0007 |
70 | 1.138 | 1.134 | 2.359 | 0.0007 |
75 | 1.224 | 1.222 | 2.5105 | 0.0007 |
80 | 1.289 | 1.286 | 2.6125 | 0.0007 |
85 | 1.327 | 1.323 | 2.662 | 0.0007 |
90 | 1.338 | 1.336 | 2.689 | 0.0007 |
95 | 1.353 | 1.351 | 2.6865 | 0.0007 |
100 | 1.335 | 1.334 | 2.642 | 0.0007 |
105 | 1.308 | 1.307 | 2.551 | 0.0007 |
110 | 1.245 | 1.242 | 2.41 | 0.0007 |
115 | 1.168 | 1.165 | 2.2775 | 0.0007 |
120 | 1.112 | 1.11 | 2.118 | 0.0007 |
125 | 1.009 | 1.005 | 1.899 | 0.0007 |
130 | 0.892 | 0.892 | 1.6605 | 0.0007 |
135 | 0.771 | 0.766 | 1.3445 | 0.0007 |
140 | 0.575 | 0.577 | 0.998 | 0.0007 |
145 | 0.423 | 0.421 | 0.75 | 0.0007 |
150 | 0.327 | 0.329 | 0.591 | 0.0007 |
155 | 0.262 | 0.264 | 0.4295 | 0.0007 |
160 | 0.165 | 0.168 | 0.231 | 0.0007 |
165 | 0.064 | 0.065 | 0.0875 | 0.0007 |
170 | 0.023 | 0.023 | 0.034 | 0.0007 |
175 | 0.011 | 0.011 | 0.019 | 0.0007 |
180 | 0.008 | 0.008 | 0.008 | 0.0007 |
Analysis
Mathematical Error
First, I will explain all of our error estimates. We used propagation of errors, ie, for any variable where is the ith components of
Intensity equation
To get the m^-2 dependence in the intensity, divide the current by an approximation to the transmittance there, which is peak/FWHM^2. noise is consistantly <1% of the current measurements and pretty stable; we will fold it into our equation. SR is more complicated. I didn't measure the distance from the light source to the photodiode, so SR is a guess. Because of this, I did not fold in the error from this, as it would be on order of 20cm/20% of the value.
Note, error of the intensity is calculated by propagation of errors of four elements (current, peak, R, FWHM, but not SR) and still ends up at almost 10%. With the SR error included, this rises to 25%-93% of each intensity point (see err_I with SR column).