Knellpoort Dam
Official nameKnellpoort Dam
LocationFree State, South Africa
Coordinates29°47′1″S 26°53′0″E / 29.78361°S 26.88333°E / -29.78361; 26.88333
Opening date1989
Operator(s)Department of Water Affairs and Forestry
Dam and spillways
Type of damgravity & arch
ImpoundsRiet Spruit
Height50 m
Length200 m
Reservoir
CreatesKnellpoort Dam Reservoir
Total capacity136 151 000 m3
Catchment area764 km2
Surface area985.4 ha

Knellpoort Dam is a combined gravity & arch type dam located on the Riet Spruit, near Wepener, Free State, South Africa. It was established in 1989. Due to siltation, the storage capacity of the Welbedacht Dam reduced rapidly from the original 115 million m3 to approximately 16 million m3 during the twenty years since completion. This reduction in storage created problems in meeting the Bloemfontein water demand at an acceptable level of reliability and as a result, the 50 m high Knellpoort Dam was completed in 1989. It was the first arch gravity roller compacted concrete (RCC) dam in the world and comprises almost 64 600 m3 rollcrete and 14 200 m3 concrete with a gross storage capacity of 136 million m3.

In order to prevent similar siltation problems to those experienced at the Welbedacht Dam, the Knellpoort Dam functions as an off-channel storage dam with a relatively small catchment area of only 764 km2 and corresponding Mean Annual Runoff (MAR) of approximately 20 million m3/a . Water from the Caledon River is pumped to Knellpoort Dam from the Tienfontein Pumping Station via a 2 km long canal which is equipped with a silt trap to reduce siltation in the main reservoir.

The dams primary purpose is to serve for municipal and industrial use and its hazard potential has been ranked high (3).