Endoscopic optical coherence tomography imaging
This article may be too technical for most readers to understand.(September 2016) |
Intracoronary Optical coherence tomography | |
---|---|
Intracoronary optical coherence tomography (OCT) (or, more generally, intravascular optical coherence tomography, IVOCT), is an endoscopic-based application of optical coherence tomography. Analogous to intravascular ultrasound, intracoronary OCT uses a catheter to deliver and collect near infrared light (e.g., 1,300 nm) to create cross-sectional images of the artery lumen and wall. Intracoronary OCT creates images at a resolution of approximately 15 micro-meters, an order of magnitude improved resolution with respect to intravascular ultrasound and X-ray coronary angiogram.[1][2]
IVOCT visualization of arteries inner lumen can help physician to understand morphology and plan treatment accordingly. IVOCT has been used as guidance for angioplasty intervention of coronary arteries, including optimization of stent implantation.
Medical uses
Data published in late 2016 showed that approximately 100,000 intracoronary optical coherence tomography procedures are performed every year, and its adoption is rapidly growing at a rate of ~ 20% every year.[3] Evidence showed that intracoronary OCT can be used to optimize percutaneous coronary intervention to treat myocardial infarction and that OCT imaging influence physician decision in > 50% of the cases.[4]
Assessment of artery lumen morphology is the cornerstone of intravascular imaging criteria to evaluate disease severity and guide intervention. The high-resolution of OCT imaging allows to assess with high accuracy vessel lumen area, wall microstructure, intracoronary stent apposition and expansion. OCT has an improved ability with respect to intravascular ultrasound to penetrate and delineate calcium in the vessel wall that makes it well suited to guide complex interventional strategies in vessels with superficial calcification. OCT has the capability of visualize coronary plaque erosion and fibrotic caps overlying atheromas.[2]
Safety
Safety of intravascular imaging, including intracoronary OCT and intravascular ultrasound, has been investigated by several studies. Recent clinical trials reported a very low rate of self-limiting, minor complications on over 3,000 patients where in all cases no harm or prolongation of hospital stay was observed. Intracoronary optical coherence tomography was demonstrated to be safe among heterogeneous groups of patients presenting varying clinical setting.[5]
Methods
State-of-the-art intracoronary optical coherence tomography uses a swept-source laser to make OCT images at high-speed (i.e., approximately 80,000 kHz - A-scan lines per second) to complete acquisition of a 3D OCT volume of coronary segments in a few-seconds.[6] The first intravascular FD-OCT was introduced to the market in 2009 (EU and Asia) and in 2012 (USA). In 2018, two intracoronary OCT catheters are clinically available for use in the coronary arteries, having a size in diameter between 2.4F and 2.7F. The basic principle of FD-OCT, is the use of interferometric techniques to measure the time-of-flight of light, emitted and collected from the imaging catheter to create cross-sectional images of arterial lumen and vessel wall.
The axial resolution of state-of-the-art commercial systems is < 20 micro-meters, which is decoupled from the catheter lateral resolution. The highest resolution of OCT allows for the in vivo imaging of vessel microstructural features at an unprecedented level, enabling visualization of vessel wall atherosclerosis, pathology, and interaction with therapeutic devices at a microscopic level.
See also
References
- ^ Bezerra, Hiram G.; Costa, Marco A.; Guagliumi, Giulio; Rollins, Andrew M.; Simon, Daniel I. (2009). "Intracoronary Optical Coherence Tomography: A Comprehensive Review". JACC: Cardiovascular Interventions. 2 (11): 1035–1046. doi:10.1016/j.jcin.2009.06.019. ISSN 1936-8798. PMC 4113036. PMID 19926041.
- ^ a b Tearney, Guillermo J.; Regar, Evelyn; Akasaka, Takashi; Adriaenssens, Tom; Barlis, Peter; Bezerra, Hiram G.; Bouma, Brett; Bruining, Nico; Cho, Jin-man; Chowdhary, Saqib; Costa, Marco A.; de Silva, Ranil; Dijkstra, Jouke; Di Mario, Carlo; Dudeck, Darius; Falk, Erlin; Feldman, Marc D.; Fitzgerald, Peter; Garcia, Hector; Gonzalo, Nieves; Granada, Juan F.; Guagliumi, Giulio; Holm, Niels R.; Honda, Yasuhiro; Ikeno, Fumiaki; Kawasaki, Masanori; Kochman, Janusz; Koltowski, Lukasz; Kubo, Takashi; Kume, Teruyoshi; Kyono, Hiroyuki; Lam, Cheung Chi Simon; Lamouche, Guy; Lee, David P.; Leon, Martin B.; Maehara, Akiko; Manfrini, Olivia; Mintz, Gary S.; Mizuno, Kyiouchi; Morel, Marie-angéle; Nadkarni, Seemantini; Okura, Hiroyuki; Otake, Hiromasa; Pietrasik, Arkadiusz; Prati, Francesco; Räber, Lorenz; Radu, Maria D.; Rieber, Johannes; Riga, Maria; Rollins, Andrew; Rosenberg, Mireille; Sirbu, Vasile; Serruys, PatrickmW.J.C.; Shimada, Kenei; Shinke, Toshiro; Shite, Junya; Siegel, Eliot; Sonada, Shinjo; Suter, Melissa; Takarada, Shigeho; Tanaka, Atsushi; Terashima, Mitsuyasu; Troels, Thim; Uemura, Shiro; Ughi, Giovanni J.; van Beusekom, Heleen M.M.; van der Steen, Antonius F.W.; van Es, Gerrit-Ann; van Soest, Gijs; Virmani, Renu; Waxman, Sergio; Weissman, Neil J.; Weisz, Giora (2012). "Consensus Standards for Acquisition, Measurement, and Reporting of Intravascular Optical Coherence Tomography Studies". Journal of the American College of Cardiology. 59 (12): 1058–1072. doi:10.1016/j.jacc.2011.09.079. ISSN 0735-1097. PMID 22421299.
- ^ Swanson, Eric (13 June 2016). "Optical Coherence Tomography: Beyond better clinical care: OCT's economic impact". BioOptics World. Retrieved 9 September 2016.
- ^ Wijns, William; Shite, Junya; Jones, Michael R.; Lee, Stephen W.-L.; Price, Matthew J.; Fabbiocchi, Franco; Barbato, Emanuele; Akasaka, Takashi; Bezerra, Hiram; Holmes, David (2015). "Optical coherence tomography imaging during percutaneous coronary intervention impacts physician decision-making: ILUMIEN I study". European Heart Journal. 36 (47): 3346–3355. doi:10.1093/eurheartj/ehv367. ISSN 0195-668X. PMC 4677272. PMID 26242713.
- ^ Johannes N. van der Sijde, Antonios Karanasos, Nienke S. van Ditzhuijzen, Takayuki Okamura, Robert-Jan van Geuns, Marco Valgimigli, Jurgen M. R. Ligthart, Karen T. Witberg, Saskia Wemelsfelder, Jiang Ming Fam, BuChun Zhang, Roberto Diletti, Peter P. de Jaegere, Nicolas M. van Mieghem, Gijs van Soest, Felix Zijlstra, Ron T. van Domburg and Evelyn Regar (2016). "Safety of optical coherence tomography in daily practice: a comparison with intravascular ultrasound". European Heart Journal - Cardiovascular Imaging. 18 (4): 467–474. doi:10.1093/ehjci/jew037. PMID 26992420.
{{cite journal}}
: CS1 maint: multiple names: authors list (link) - ^ S. H. Yun, G. Tearney, J. de Boer & B. Bouma (2004). "Pulsed-source and swept-source spectral-domain optical coherence tomography with reduced motion artifacts". Optics Express. 12 (23): 5614–5624. Bibcode:2004OExpr..12.5614Y. doi:10.1364/opex.12.005614. PMC 2713045. PMID 19488195.
{{cite journal}}
: CS1 maint: multiple names: authors list (link)