Jump to content

Air displacement plethysmography

From Wikipedia, the free encyclopedia

This is an old revision of this page, as edited by Welsh (talk | contribs) at 07:40, 2 January 2016 (Link repair: Multi-compartment models -> Multi-compartment model - You can help!). The present address (URL) is a permanent link to this revision, which may differ significantly from the current revision.

Body composition measurement in adults with Whole-Body Air Displacement Plethysmography (ADP) technology
Body composition measurement in infants with Whole-Body Air Displacement Plethysmography (ADP) technology

Air displacement plethysmography or ADP (also known as Whole-body air displacement plethysmography) is a recognized and scientifically validated densitometric method to measure human body composition. ADP is based on the same principles as the Gold Standard method of hydrostatic weighing, but through a densitometric technique that uses air displacement rather than water immersion. Air-displacement plethysmography offers several advantages over established reference methods, including a quick, comfortable, automated, noninvasive, and safe measurement process, and accommodates various subject types (e.g., children, obese, elderly, and disabled persons).[1]

ADP History

The principles of plethysmography were first applied to the measurement of the body volume and composition of infants in the early 1900s, but it was not until the 1960s that relatively stable measurements were achieved. However, these systems required that ambient conditions be maintained constant. Applications in humans have been limited, in part by technical difficulties in adjusting for irregularities in temperature and humidity of the air next to the skin and the air. Because of inconveniences such as these and various technology difficulties, none of the early air-displacement plethysmographs were ever developed for common, everyday use.[1]

Later experimental air-displacement plethysmographs developed in the 1980s were more advanced technologically, but it was only in the mid-1990s, that the first commercially available air-displacement plethysmograph was introduced for adultsCite error: The <ref> tag has too many names (see the help page). and early 2000 for infants[2]

How It Works

With air-displacement plethysmography, the volume of an object is measured indirectly by determining the volume of air it displaces inside an enclosed chamber (plethysmograph). Thus, human body volume is measured when a subject sits inside the chamber and displaces a volume of air equal to his or her body volume. Body volume is calculated indirectly by subtracting the volume of air remaining inside the chamber when the subject is inside from the volume of air in the chamber when it is empty. The volume of air inside the chamber is calculated by slightly changing the size of the chamber (e.g. by moving a diaphragm in one of the walls) and applying relevant physical gas laws to determine the total volume from the changing air pressure within the chamber as its size is altered. Boyle's law states that at a constant temperature, Volume (V) and Pressure (P) are inversely related. Therefore, when a constant temperature is maintained (isothermal conditions), Boyle's law can be applied. Consequently, most early plethysmographs required temperature-controlled surroundings and isothermal conditions within the test chamber. This problem was not fully resolved until systems were developed that do not require isothermal testing conditions.[1]

Validations

Air Displacement Plethysmographs have been validated against main body composition assessment techniques:

References

See also