English: This image shows the salient portion of the official NASA procedure for dealing with a high pressure indication on the cryogenic oxygen tank. It prompts for action to reduce the pressure, to include:

- Turning the four tank heaters and fans off (switch position to center)
- Pulling the two heater circuit breakers (cb) to open to remove the energy source
- Perform a 2-minute purge on all three Fuel Cells (FC), or directly opening the O2 valve (counter-clockwise)

The following is the description presented in Appendix A, page A-162 of the Cortright Report:



5.0 FUEL CELL/CRYOGENIC SUBSYSTEM MALFUNCTION PROCEDURES

The procedures describe the proper order and nature of emergency steps the crew must perform to determine the source of a fuel cell or cryogenic storage system problem/malfunction. A Caution and Warning alarm and light or abnormal instrumentation indication is evaluated by a malfunction procedure logic diagram. The logic diagrams enable the crew to determine the source of the problem and corrective actions, if required. Fuel cell shutdown and bus short isolation (not related to Caution and Warning) procedures are also presented as part of the malfunction procedures.

The procedures are primarily used as a guide for the flight crew to locate a problem and are presented for the flight monitor as a guide to the crew actions.

The source of the data was CSM 108 (Apollo 12) Flight Malfunction Procedures.


Date
Source REPORT OF APOLLO 13 REVIEW BOARD (The Cortright Report)
Author Edgar M. Cortright, et al

Licensing

Public domain This file is in the public domain in the United States because it was solely created by NASA. NASA copyright policy states that "NASA material is not protected by copyright unless noted". (See Template:PD-USGov, NASA copyright policy page or JPL Image Use Policy.)
Warnings:

Captions

Add a one-line explanation of what this file represents

Items portrayed in this file

depicts

June 1970

image/png

ac869635680e783b006b2b1fbb9cbec132cb3406

325,215 byte

1,024 pixel

1,280 pixel

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current09:56, 15 March 2010Thumbnail for version as of 09:56, 15 March 20101,280 × 1,024 (318 KB)Tdadamemd{{Information |Description={{en|1=This image shows the salient portion of the official NASA procedure for dealing with a high pressure indication on the cryogenic oxygen tank. It prompts for action to reduce the pressure, to include:<br><br> - Turning the
No pages on the English Wikipedia use this file (pages on other projects are not listed).