The Gletscherbahn Kaprun 2 funicular train is waiting at the lower valley station. The train involved in the disaster entered the tunnel where it caught fire 600 meters from the lower end. The tunnel entrance is visible in the background.

The Kaprun disaster was a fire that occurred in an ascending train in the tunnel of the Gletscherbahn Kaprun 2 funicular in Kaprun, Austria, on 11 November 2000. The disaster claimed the lives of 155 people, leaving 12 survivors (10 Germans and two Austrians) from the burning train. The victims were skiers on their way to the Kitzsteinhorn Glacier.

The train

The Gletscherbahn Kaprun 2 was a funicular railway running from Kaprun to the Kitzsteinhorn, opened in 1974. In 1993, it was modernized, giving the trains a sleek, futuristic look; also making them the pride of Austria's ski resorts. This railway had the unusual track gauge of 946 mm (3 ft 1+14 in) and a length of 3,900 metres (12,800 ft), having 3,300 metres (10,800 ft) of track inside a tunnel. The train climbed and descended the tunnel at 25 km/h, angled at 30 degrees. There were two carriages on a single track, with a section allowing them to pass each other halfway. One carried passengers up the mountain while its twin simultaneously descended. The tunnel terminated at the main reception centre, called the Alpine Centre, where a powerful motorized winch system pulled the wagons. There were neither engines, fuel tanks, nor drivers, only low-voltage electrical systems, 160-liter hydraulic tanks (used for the braking system) and an attendant who operated the hydraulic doors. Each train had four passenger compartments and a cab at front and rear for the attendant, who switched back and forth as they travelled up and down. It could carry up to 180 passengers.

The unit had its fire extinguishers out of the passengers' reach in the sealed attendants' compartments. No smoke detectors existed on board. The passengers had no method of contacting the attendant. Professor Joseph Nejez, a funicular train expert, said that the designers throughout the years had a perception that a fire could not occur since no fire occurred in a funicular cabin prior to the Kaprun disaster. The train complied with area safety codes, which did not address the systems installed on the train during its 1993 upgrade. The onboard electric power, hydraulic braking systems, and fan heaters intended for use in homes instead of trains increased the likelihood of fire.[1][unreliable source?]

It was recently reported that a new funicular carriage would be constructed to run on the same track formerly used by the Gletscherbahn Kaprun 2, but will only carry freight from the village of Kaprun to the Alpine Centre, and will not be for passenger use.[citation needed]

The disaster

On 11 November 2000, 161 passengers and one conductor boarded the funicular train for an early morning trip to the slopes. After the passenger train ascended into the tunnel shortly after 9:00 am, the electric fan heater in the unattended cabin at the lower end of the train caught fire, due to a design fault that caused the unit to over-heat[dubiousdiscuss]. The fire melted through plastic pipes carrying flammable hydraulic fluid from the braking system, resulting in the loss of fluid pressure which caused the train to halt unexpectedly 600 meters into the tunnel (this was a standard safety feature). Several minutes later, the train conductor, who was in the cabin at the upper end of the train (which was the front, since the train was ascending), realized a fire had broken out, reported it to the control centre, and attempted to open the hydraulically operated doors, but the system pressure loss prevented them from operating. The train conductor then lost contact with the control centre because the fire burned through a 16kV power cable running alongside the length of the track, causing a total blackout throughout the entire ski resort.

The passengers, by this stage aware of the fire and unable to exit through the doors, attempted to smash the break-resistant acrylic glass windows in order to escape. 12 people from the rear of the train who successfully broke a window followed the advice of another escapee who had been a volunteer fire fighter for 20 years, and escaped downwards past the fire and below the smoke.

Many of the still-trapped occupants had by now lost consciousness due to toxic fumes. Eventually, the conductor was able to unlock the doors, allowing them to be manually forced open by the remaining conscious passengers who spilled out into the tunnel and fled upwards and away from the fire. The tunnel acted like a giant blast furnace, sucking oxygen in from the bottom and rapidly sent the poisonous smoke, heat and the fire itself billowing upwards. All the passengers ascending on foot, as well as the train conductor, were asphyxiated by the smoke and then burned by the raging fire.

The conductor and the sole passenger on the railway's second train, which was descending the mountain in the same tunnel from above the burning carriage, also died of smoke inhalation. The smoke kept ascending the tunnel, reaching the Alpine Centre located at the top end of the track 2,500 m (8,200 ft) away. Two fleeing workers in the Alpine Centre, upon seeing the smoke, alerted employees and customers and escaped via an emergency exit. They mistakenly left the exit doors open, a factor which increased the chimney effect within the tunnel by allowing air to escape upwards more quickly and further intensifying the fire. Meanwhile, the centre was filled with smoke and all except four people escaped the centre. Firefighters reached the center and saved one of the four, while the other three were asphyxiated.

The twelve survivors of the disaster were the passengers who travelled downhill past the fire at the rear of the train, escaping the upward-rising toxic fumes and smoke.

Nearly one year after the fire, the official inquiry determined the cause was the failure, overheating and ignition of one of the fan heaters installed in the conductor's compartments that were not designed for use in a moving vehicle. The ignition was caused when a design fault caused the unit to over-heat, which in turn causes the plastic mount for the heater element to break off, causing the element to jam against its plastic casing and catch fire. A slow leak of highly flammable hydraulic oil was ignited by the burning, melting heater, which in turn melted the plastic fluid lines further feeding the flames, and also resulting in the hydraulic pressure loss which caused the train to stop and the doors to fail.

Casualties and aftermath

The funicular was never re-opened after the disaster and was replaced by a gondola lift, a 24-person Gletscherjet 1 funitel. The stations were abandoned and the tunnel sealed, and it remains unused today. The victims of the disaster included:[2]

Nationality Deaths
Austria Austria 92
Germany Germany 37
Japan Japan 10
United States United States of America 8
Slovenia Slovenia 4
Netherlands Netherlands 2
United Kingdom United Kingdom 1
Czech Republic Czech Republic 1
Total 155

The most notable victim was Sandra Schmitt, a 19-year-old German freestyle skier who at the time was the reigning Women's Dual Moguls World Champion.[3]

On 19 February 2004, Judge Manfred Seiss acquitted all 16 suspects – including company officials, technicians and government inspectors – clearing them of criminal negligence. Judge Seiss said there was insufficient evidence to find the suspects responsible for the conditions that led to the blaze. On 25 September 2007, the public prosecutor's office in Heilbronn determined that the manufacturer of the electric heater was not responsible.[citation needed]

The Austrian Nobel Prize winner Elfriede Jelinek incorporated the disaster in her 2003 play In den Alpen (In the Alps).

References

  1. ^ "Fire on the Ski Slope." "Seconds From Disaster".
  2. ^ "Flashback: Kaprun ski train fire". BBC News. 19 February 2004. Archived from the original on 7 December 2013. Retrieved 14 April 2009.
  3. ^ "Obituary – Sandra Schmitt". The Guardian. 17 November 2000. Archived from the original on 24 June 2012. Retrieved 6 January 2012.

External links

47°13′32.26″N 12°43′14.67″E / 47.2256278°N 12.7207417°E / 47.2256278; 12.7207417