Jump to content

Neutron backscattering

From Wikipedia, the free encyclopedia

This is the current revision of this page, as edited by Fizzicks (talk | contribs) at 20:18, 24 January 2024 (Backscattering spectrometers). The present address (URL) is a permanent link to this version.

(diff) ← Previous revision | Latest revision (diff) | Newer revision → (diff)

Neutron backscattering is one of several inelastic neutron scattering techniques. Backscattering from monochromator and analyzer crystals is used to achieve an energy resolution on the order of a microelectronvolt (μeV). Neutron backscattering experiments are performed to study atomic or molecular motion on a nanosecond time scale.

History

[edit]

Neutron backscattering was proposed by Heinz Maier-Leibnitz in 1966,[1] and realized by some of his students in a test setup at the research reactor FRM I in Garching bei München, Germany.[2] Following this successful demonstration of principle, permanent spectrometers were built at Forschungszentrum Jülich and at the Institut Laue-Langevin (ILL). Later instruments brought an extension of the accessible momentum transfer range (IN13 at ILL), the introduction of focussing optics (IN16 at ILL), and a further increase of intensity by a compact design with a phase-space transform chopper (HFBS at NIST, SPHERES at FRM II, IN16B at the Institut Laue-Langevin).

Backscattering spectrometers

[edit]

Operational backscattering spectrometers at reactors include IN10, IN13, and IN16B at the Institut Laue-Langevin, the High Flux Backscattering Spectrometer (HFBS) at the NIST Center for Neutron Research,[3] the SPHERES instrument of Forschungszentrum Jülich at FRM II[4] and EMU at ANSTO.

Inverse geometry spectrometers

[edit]

Inverse geometry spectrometers at spallation sources include IRIS and OSIRIS at the ISIS neutron source at Rutherford-Appleton, BASIS at the Spallation Neutron Source, and MARS at the Paul Scherrer Institute

Historic instruments

[edit]

Historic instruments are the first backscattering spectrometer that was a temporary setup at FRM I and the backscattering spectrometer BSS (also called PI) at the DIDO reactor of the Forschungszentrum Jülich (decommissioned).[5]

References

[edit]
  1. ^ H. Maier-Leibnitz: Grundlagen für die Beurteilung von Intensitäts- und Genauigkeitsfragen bei Neutronenstreumessungen, Nukleonik 8, 61 (1966).
  2. ^ Alefeld, B.; Birr, M.; Heidemann, A. (1969). "Ein neues hochauflösendes Neutronenkristallspektrometer und seine Anwendung". Die Naturwissenschaften. 56 (8): 410–412. Bibcode:1969NW.....56..410A. doi:10.1007/BF00593617. ISSN 0028-1042. S2CID 42571268.
  3. ^ Meyer, A.; Dimeo, R. M.; Gehring, P. M.; Neumann, D. A. (2003). "The high-flux backscattering spectrometer at the NIST Center for Neutron Research". Review of Scientific Instruments. 74 (5): 2759. arXiv:cond-mat/0209153. Bibcode:2003RScI...74.2759M. doi:10.1063/1.1568557. ISSN 0034-6748. S2CID 56300356.
  4. ^ Wuttke, Joachim; Budwig, Alfred; Drochner, Matthias; Kämmerling, Hans; Kayser, Franz-Joseph; Kleines, Harald; Ossovyi, Vladimir; Pardo, Luis Carlos; Prager, Michael; Richter, Dieter; Schneider, Gerald J.; Schneider, Harald; Staringer, Simon (2012). "SPHERES, Jülich's high-flux neutron backscattering spectrometer at FRM II". Review of Scientific Instruments. 83 (7): 075109. arXiv:1204.3415. Bibcode:2012RScI...83g5109W. doi:10.1063/1.4732806. ISSN 0034-6748. PMID 22852726. S2CID 3862676.
  5. ^ A historical and updated review on neutron backscattering and its applications can be found on WEB-site of Neutron Backscattering Spectroscopy and a more recent version of it at http://www.astrosurf.com/heidemann/bsweb/index.htm/