Operational modal analysis

From Wikipedia, the free encyclopedia

This is an old revision of this page, as edited by 141.225.166.228 (talk) at 19:20, 30 December 2015 (Methods). The present address (URL) is a permanent link to this revision, which may differ significantly from the current revision.

Ambient modal identification, also known as Operational Modal Analysis (OMA), aims at identifying the modal properties of a structure based on vibration data collected when the structure is under its operating conditions, i.e., no initial excitation or known artificial excitation. The modal properties of a structure include primarily the natural frequencies, damping ratios and mode shapes. In an ambient vibration test the subject structure can be under a variety of excitation sources which are not measured but are assumed to be 'broadband random'. The latter is a notion that one needs to apply when developing an ambient identification method. The specific assumptions vary from one method to another. Regardless of the method used, however, proper modal identification requires that the spectral characteristics of the measured response reflect the properties of the modes rather than those of the excitation.

Pros and Cons

Implementation economy is one primary advantage of ambient vibration tests as only the (output) vibration of the structure needs to be measured. This is particularly attractive for civil engineering structures (e.g., buildings, bridges) where it can be expensive or disruptive to carry out free vibration or forced vibration tests (with known input).

Identifying modal properties using ambient data does have disadvantages:

  • The identification methods are more sophisticated. As the loading is not measured, in the development of identification method it needs to be modeled (by some stochastic process) or its dynamic effects on the measured response have to be removed. Otherwise it is not possible to explain the characteristics in the data based solely on the modal properties.
  • Without loading information the identified modal properties can have significant identification uncertainties. In particular, the results are as good as the broadband assumption applied.
  • The identified modal properties only reflect the properties at the ambient vibration level, which is usually lower than the serviceability level or other design cases of interest. This is especially relevant for the damping ratio which is commonly perceived to be amplitude-dependent.

Methods

Methods of OMA can be broadly classified by two aspects, 1) frequency domain or time domain, and 2) Bayesian or non-Bayesian. Non-Bayesian methods were developed earlier than Bayesian ones. They make use of some statistical estimators with known theoretical properties for identification, e.g., the correlation function or spectral density of measured vibrations. Common non-Bayesian methods include stochastic subspace identification[1](time domain) and frequency domain decomposition (frequency domain). Bayesian methods have been developed in the time-domain[2] and frequency-domain[3][4][5]

frequency domain and time domain Operational modal analysis of structures

The objective of operational modal analysis is to extract resonant frequencies, damping, and/or operating shapes (unscaled mode shapes) of a structure. This method sometime called output-only modal analysis because only the response of the structure is measured. The structure might be excited using natural operating conditions or some other excitations might be applied to the structure;[6] however, as long as the operating shapes are not scaled based on the applied force, it is called operational modal analysis (e.g. operating shapes of a wind turbine blade excited by a shaker are measured using operating modal analysis [7] ). This method has been used to extract operating modes of a hovering helicopter.[8]

See also

References

  1. ^ Van Overschee, P.; De Moor, B. (1996). Subspace Identification for Linear Systems. Boston: Kluwer Academic Publisher.
  2. ^ Yuen, K.V.; Katafygiotis, L.S. (2001). "Bayesian time-domain approach for modal updating using ambient data". Probabilistic Engineering Mechanics. 16 (3): 219–231. doi:10.1016/S0266-8920(01)00004-2.
  3. ^ Yuen, K.V.; Katafygiotis, L.S. (2001). "Bayesian spectral density approach for modal updating using ambient data". Earthquake Engineering and Structural Dynamics. 30: 1103–1123. doi:10.1002/eqe.53.
  4. ^ Yuen, K.V.; Katafygiotis, L.S. (2003). "Bayesian Fast Fourier Transform approach for modal updating using ambient data". Advances in Structural Engineering. 6 (2): 81–95. doi:10.1260/136943303769013183.
  5. ^ Au, S.K.; Zhang, F.L.; Ni, Y.C. (2013). "Bayesian operational modal analysis: theory, computation, practice". Computers and Structures. 126: 3–14. doi:10.1016/j.compstruc.2012.12.015.
  6. ^ Improved Modal Characterization Using Hybrid Data
  7. ^ Using Stereophotogrammetry to Measure Vibrations of a Wind Turbine Blade
  8. ^ Using Stereophotogrammetry to collect operating data on a helicopter