Silt density index
The silt density index is a measure for the fouling capacity of water in reverse osmosis systems. The test measures the rate at which a 0.45-micrometre filter is plugged when subjected to a constant water pressure of 206.8 kPa (30 psi). The SDI gives the percent drop per minute in the flow rate of the water through the filter, averaged over a period of time such as 15 minutes.[citation needed][1]
Typically, spiral-wound reverse osmosis systems will need an SDI less than 5, and hollow fiber reverse osmosis systems will need an SDI less than 3. In these kinds of systems, deep-well waters (with a typical SDI of 3) could be used straight from the source. If fed from surface waters (with a typical SDI greater than 6), the water will need to be filtered before use.[citation needed] Seawater desalination plants utilising reverse osmosis systems also need very efficient filtering due to the typically high but variable SDI of seawater.[2]
References
- ^ Procedure and calculation
- ^ "Pilot Plant Results Demonstrating Feasibility and Perfomance [sic] of SWRO on Gulf Water (Synopsis)". IDS Water. Archived from the original on March 20, 2013. Retrieved May 28, 2015.
{{cite web}}
: Cite has empty unknown parameter:|1=
(help); Unknown parameter|deadurl=
ignored (|url-status=
suggested) (help)