Jump to content

Twyman–Green interferometer

From Wikipedia, the free encyclopedia

This is an old revision of this page, as edited by Citation bot (talk | contribs) at 08:20, 5 November 2015 (Removed parameters. You can use this bot yourself. Report bugs here.). The present address (URL) is a permanent link to this revision, which may differ significantly from the current revision.

Figure 1. Twyman-Green Interferometer.

A Twyman–Green interferometer is a variant of the Michelson interferometer principally used to test optical components.[1] It was introduced in 1916 by Frank Twyman[2] and Arthur Green.

Fig. 1 illustrates a Twyman–Green interferometer set up to test a lens. Light from a laser is expanded by a diverging lens (not shown), then is collimated into a parallel beam. A convex spherical mirror is positioned so that its center of curvature coincides with the focus of the lens being tested. The emergent beam is recorded by an imaging system for analysis.[3]

The fixed mirror in the Michelson interferometer is rotatable in the Twyman–Green interferometer, and while the light source is usually an extended source (although it can also be a laser) in a Michelson interferometer, the light source is always a point-like source in the Twyman–Green interferometer. The rotation of one mirror results in straight fringes appearing in the interference pattern, a fringing which is used to test the quality of optical components by observing changes in the fringe pattern when the component is placed in one arm of the interferometer.

References

  1. ^ Malacara, D. (2007). "Twyman–Green Interferometer". Optical Shop Testing. p. 46. doi:10.1002/9780470135976.ch2. ISBN 9780470135976.
  2. ^ Menzies, A. C. (1960). "Frank Twyman. 1876-1959". Biographical Memoirs of Fellows of the Royal Society. 5. Royal Society publishing: 269–279. doi:10.1098/rsbm.1960.0020. ISSN 0080-4606.
  3. ^ "Interferential Devices - Twyman-Green Interferometer". OPI - Optique pour l'Ingénieur. Retrieved 4 April 2012.