Universal asynchronous receiver/transmitter

From Wikipedia, the free encyclopedia
Jump to: navigation, search

A universal asynchronous receiver/transmitter, abbreviated UART /ˈjuːɑrt/, is a piece of computer hardware that translates data between parallel and serial forms. UARTs are commonly used in conjunction with communication standards such as EIA, RS-232, RS-422 or RS-485. The universal designation indicates that the data format and transmission speeds are configurable. The electric signaling levels and methods (such as differential signaling etc.) are handled by a driver circuit external to the UART.

A UART is usually an individual (or part of an) integrated circuit used for serial communications over a computer or peripheral device serial port. UARTs are now commonly included in microcontrollers. A dual UART, or DUART, combines two UARTs into a single chip. An octal UART or OCTART combines eight UARTs into one package, an example being the NXP SCC2698. Many modern ICs now come with a UART that can also communicate synchronously; these devices are called USARTs (universal synchronous/asynchronous receiver/transmitter).

Transmitting and receiving serial data[edit]

The universal asynchronous receiver/transmitter (UART) takes bytes of data and transmits the individual bits in a sequential fashion.[1] At the destination, a second UART re-assembles the bits into complete bytes. Each UART contains a shift register, which is the fundamental method of conversion between serial and parallel forms. Serial transmission of digital information (bits) through a single wire or other medium is less costly than parallel transmission through multiple wires.

The UART usually does not directly generate or receive the external signals used between different items of equipment. Separate interface devices are used to convert the logic level signals of the UART to and from the external signalling levels. External signals may be of many different forms. Examples of standards for voltage signaling are RS-232, RS-422 and RS-485 from the EIA. Historically, current (in current loops) was used in telegraph circuits. Some signaling schemes do not use electrical wires. Examples of such are optical fiber, IrDA (infrared), and (wireless) Bluetooth in its Serial Port Profile (SPP). Some signaling schemes use modulation of a carrier signal (with or without wires). Examples are modulation of audio signals with phone line modems, RF modulation with data radios, and the DC-LIN for power line communication.

Communication may be simplex (in one direction only, with no provision for the receiving device to send information back to the transmitting device), full duplex (both devices send and receive at the same time) or half duplex (devices take turns transmitting and receiving).

Character framing[edit]

The right-most (least significant) data bit is always transmitted first. If parity is present, the parity bit comes after the data bits but before the stop bit(s).
Bit number 1 2 3 4 5 6 7 8 9 10 11
Start bit 5–8 data bits Stop bit(s)
Start Data 0 Data 1 Data 2 Data 3 Data 4 Data 5 Data 6 Data 7 Stop

The idle, no data state is high-voltage, or powered. This is a historic legacy from telegraphy, in which the line is held high to show that the line and transmitter are not damaged. Each character is sent as a logic low start bit, a configurable number of data bits (usually 8, but users can choose 5 to 8 or 9 bits depending on which UART is in use), an optional parity bit if the number of bits per character chosen is not 9 bits, and one or more logic high stop bits.

The start bit signals the receiver that a new character is coming. The next five to nine bits, depending on the code set employed, represent the character. If a parity bit is used, it would be placed after all of the data bits. The next one or two bits are always in the mark (logic high, i.e., '1') condition and called the stop bit(s). They signal the receiver that the character is completed. Since the start bit is logic low (0) and the stop bit is logic high (1) there are always at least two guaranteed signal changes between characters.

If the line is held in the logic low condition for longer than a character time, this is a break condition that can be detected by the UART.

Receiver[edit]

All operations of the UART hardware are controlled by a clock signal which runs at a multiple of the data rate, typically 8 times the bit rate. The receiver tests the state of the incoming signal on each clock pulse, looking for the beginning of the start bit. If the apparent start bit lasts at least one-half of the bit time, it is valid and signals the start of a new character. If not, it is considered a spurious pulse and is ignored. After waiting a further bit time, the state of the line is again sampled and the resulting level clocked into a shift register. After the required number of bit periods for the character length (5 to 8 bits, typically) have elapsed, the contents of the shift register are made available (in parallel fashion) to the receiving system. The UART will set a flag indicating new data is available, and may also generate a processor interrupt to request that the host processor transfers the received data.

Communicating UARTs usually have no shared timing system apart from the communication signal. Typically, UARTs resynchronize their internal clocks on each change of the data line that is not considered a spurious pulse. Obtaining timing information in this manner, they reliably receive when the transmitter is sending at a slightly different speed than it should. Simplistic UARTs do not do this, instead they resynchronize on the falling edge of the start bit only, and then read the center of each expected data bit, and this system works if the broadcast data rate is accurate enough to allow the stop bits to be sampled reliably.

It is a standard feature for a UART to store the most recent character while receiving the next. This "double buffering" gives a receiving computer an entire character transmission time to fetch a received character. Many UARTs have a small first-in, first-out FIFO buffer memory between the receiver shift register and the host system interface. This allows the host processor even more time to handle an interrupt from the UART and prevents loss of received data at high rates.

Transmitter[edit]

Transmission operation is simpler since it is under the control of the transmitting system. As soon as data is deposited in the shift register after completion of the previous character, the UART hardware generates a start bit, shifts the required number of data bits out to the line, generates and appends the parity bit (if used), and appends the stop bits. Since transmission of a single character may take a long time relative to CPU speeds, the UART will maintain a flag showing busy status so that the host system does not deposit a new character for transmission until the previous one has been completed; this may also be done with an interrupt. Since full-duplex operation requires characters to be sent and received at the same time, UARTs use two different shift registers for transmitted and received characters.

Application[edit]

Transmitting and receiving UARTs must be set for the same bit speed, character length, parity, and stop bits for proper operation. The receiving UART may detect some mismatched settings and set a "framing error" flag bit for the host system; in exceptional cases the receiving UART will produce an erratic stream of mutilated characters and transfer them to the host system.

Typical serial ports used with personal computers connected to modems use eight data bits, no parity, and one stop bit; for this configuration the number of ASCII characters per second equals the bit rate divided by 10.

Some very low-cost home computers or embedded systems dispense with a UART and use the CPU to sample the state of an input port or directly manipulate an output port for data transmission. While very CPU-intensive (since the CPU timing is critical), the UART chip can thus be omitted, saving money and space. The technique is known as bit-banging.

Synchronous transmission[edit]

USART chips have both synchronous and asynchronous modes. In synchronous transmission, the clock data is recovered separately from the data stream and no start/stop bits are used. This improves the efficiency of transmission on suitable channels since more of the bits sent are usable data and not character framing. An asynchronous transmission sends no characters over the interconnection when the transmitting device has nothing to send; but a synchronous interface must send "pad" characters to maintain synchronization between the receiver and transmitter. The usual filler is the ASCII "SYN" character. This may be done automatically by the transmitting device.

History[edit]

Some early telegraph schemes used variable-length pulses (as in Morse code) and rotating clockwork mechanisms to transmit alphabetic characters. The first UART-like devices (with fixed-length pulses) were rotating mechanical switches (commutators). Various character codes using 5, 6, 7, or 8 data bits became common in teleprinters and later as computer peripherals. Gordon Bell designed the UART for the PDP series of computers. The teletypewriter made an excellent general-purpose I/O device for a small computer. To reduce costs, including wiring and back-plane costs, these computers also pioneered flow control using XON and XOFF characters rather than hardware wires.

Western Digital made the first single-chip UART WD1402A around 1971; this was an early example of a medium scale integrated circuit. Another popular chip was a SCN2651 from the Signetics 2650 family.

An example of an early 1980s UART was the National Semiconductor 8250. In the 1990s, newer UARTs were developed with on-chip buffers. This allowed higher transmission speed without data loss and without requiring such frequent attention from the computer. For example, the popular National Semiconductor 16550 has a 16 byte FIFO, and spawned many variants, including the 16C550, 16C650, 16C750, and 16C850.

Depending on the manufacturer, different terms are used to identify devices that perform the UART functions. Intel called their 8251 device a "Programmable Communication Interface". MOS Technology 6551 was known under the name "Asynchronous Communications Interface Adapter" (ACIA). The term "Serial Communications Interface" (SCI) was first used at Motorola around 1975 to refer to their start-stop asynchronous serial interface device, which others were calling a UART. Zilog manufactured a number of Serial Communication Controllers or SCCs.

Structure[edit]

A UART usually contains the following components:

  • a clock generator, usually a multiple of the bit rate to allow sampling in the middle of a bit period.
  • input and output shift registers
  • transmit/receive control
  • read/write control logic
  • transmit/receive buffers (optional)
  • parallel data bus buffer (optional)
  • First-in, first-out (FIFO) buffer memory (optional)

Special receiver conditions[edit]

Overrun error[edit]

An "overrun error" occurs when the receiver cannot process the character that just came in before the next one arrives. Various devices have different amounts of buffer space to hold received characters. The CPU must service the UART in order to remove characters from the input buffer. If the CPU does not service the UART quickly enough and the buffer becomes full, an Overrun Error will occur, and incoming characters will be lost.

Underrun error[edit]

An "underrun error" occurs when the UART transmitter has completed sending a character and the transmit buffer is empty. In asynchronous modes this is treated as an indication that no data remains to be transmitted, rather than an error, since additional stop bits can be appended. This error indication is commonly found in USARTs, since an underrun is more serious in synchronous systems.

Framing error[edit]

A "framing error" occurs when the designated "start" and "stop" bits are not found. As the "start" bit is used to identify the beginning of an incoming character, it acts as a reference for the remaining bits. If the data line is not in the expected state (hi/lo) when the "stop" bit is expected, a Framing Error will occur.

Parity error[edit]

A Parity Error occurs when the parity of the number of 1 bits disagrees with that specified by the parity bit. Use of a parity bit is optional, so this error will only occur if parity-checking has been enabled.

Break condition[edit]

A "break condition" occurs when the receiver input is at the "space" level for longer than some duration of time, typically, for more than a character time. This is not necessarily an error, but appears to the receiver as a character of all zero bits with a framing error. The term "break" derives from current loop signaling, which was the traditional signaling used for teletypewriters. The "spacing" condition of a current loop line is indicated by no current flowing, and a very long period of no current flowing is often caused by a break or other fault in the line.

Some equipment will deliberately transmit the "space" level for longer than a character as an attention signal. When signaling rates are mismatched, no meaningful characters can be sent, but a long "break" signal can be a useful way to get the attention of a mismatched receiver to do something (such as resetting itself). Unix-like systems can use the long "break" level as a request to change the signaling rate, to support dial-in access at multiple signaling rates.

UART models[edit]

Model Description
EXAR XR21V1410
Intersil 6402
CDP 1854 (RCA, now Intersil)
Zilog Z8440 2000 kbit/s. Async, Bisync, SDLC, HDLC, X.25. CRC. 4-byte RX buffer. 2-byte TX buffer. DMA.[2]
8250 Obsolete with 1-byte buffers. These UARTs' maximum standard serial port speed is 9600 bits per second if the operating system has a 1 millisecond interrupt latency.
8251
Z8530/85C30
Motorola 6850
6551
Rockwell 65C52
16450
16550 This UART's FIFO was broken, so it cannot safely run any faster than the 16450 UART. The 16550A and later versions fix this bug.
16550A This UART has 16-byte FIFO buffers. Its receive interrupt trigger levels can be set to 1, 4, 8, or 14 characters. Its maximum standard serial port speed if the operating system has a 1 milisecond interrupt latency is 115.2 kbit/s. Operating systems with lower interrupt latencies could handle higher baud rates like 230.4 kbit/s or 460.8 kbit/s. This chip can provide signals to facilitate a third party DMA controller perform DMA transfers to and from the UART. This was known as DMA mode because it was meant to be coupled with a DMA controller in this mode to perform the transfers on behalf of the CPU.[3] It was introduced by National Semiconductor, which has been sold to Texas Instruments. National Semiconductor claimed that this UART could physically run at up to 1.5 Mbit/s.
16C552
16650 This UART was introduced by Startech Semiconductor which is now owned by Exar Corporation and is not related to Startech.com. Early versions had a broken FIFO buffer and therefore cannot safely run any faster than the 16450 UART.[4] Versions of this UART that were not broken had 32-character FIFO buffers and could function at standard serial port speeds up to 230.4 kbit/s if the operating system has a 1 millisecond interrupt latency. Current versions of this UART by Exar claim to be able to physically handle up to 1.5 Mbit/s. This UART introduces the Auto-RTS and Auto-CTS features in which the RTS# signal is controlled by the UART to signal the external device to stop transmitting when the UART's buffer is full to or beyond a user-set trigger point and to stop transmitting to the device when the device drives the CTS# signal high (logic 0).
16750 64-byte buffers. This UART can handle a maximum standard serial port speed of 460.8 kbit/s if the maximum interrupt latency is 1 millisecond. This UART was introduced by Texas Instruments. TI claims that early models can run up to 1 Mbit/s physically, and later models can run up to 5 Mbit/s physically.
16850 128-byte buffers. This UART can handle a maximum standard serial port speed of 921.6 kbit/s if the maximum interrupt latency is 1 millisecond. This UART was introduced by Exar Corporation. Exar claims that early models can run up to 1.5 Mbit/s physically, and later models can run up to 6.25 Mbit/s physically.
16C850
16950 128-byte buffers. This UART can handle a maximum standard serial port speed of 921.6 kbit/s if the maximum interrupt latency is 1 millisecond and if the UART is not connected to a DMA engine or is connected to a DMA engine that is not enabled. This UART supports 9-bit characters in addition to the 5-8 bit characters other UARTs support. This was introduced by Oxford Semiconductor, which is now owned by PLX Technology. Oxford/PLX claims that this UART can run up to 15 Mbit/s physically. PCI Express variants by Oxford/PLX can safely run much faster than other variants because they are integrated with a first party bus mastering PCIe DMA engine. This DMA engine is controlled by the UART's DMA mode signals that were defined for the 16550. The DMA engine will prevent buffer overruns by moving data in the receive buffer to the host computer's memory via PCIe, and can speed up transmission by moving data to be sent in the host computer's memory to the transmit buffer if it is not full. Both of these operations do require some setup by the CPU, but are automated by the UART and the DMA engine after setup is complete.
16C950
16954 Quad port version of the 16950/16C950. 128-byte buffers per port. This UART can handle a maximum standard serial port speed of 921.6 kbit/s if the maximum interrupt latency is 1 millisecond and if the UART is not connected to a DMA engine or is connected to a DMA engine that is not enabled. This UART supports 9-bit characters in addition to the 5-8 bit characters other UARTs support. This was introduced by Oxford Semiconductor, which is now owned by PLX Technology. Oxford/PLX claims that this UART can run up to 15 Mbit/s physically. PCI Express variants by Oxford/PLX can safely run much faster than other variants because they are integrated with a first party bus mastering PCIe DMA engine. This DMA engine is controlled by the UART's DMA mode signals that were defined for the 16550. The DMA engine will prevent buffer overruns by moving data in the receive buffer to the host computer's memory via PCIe, and can speed up transmission by moving data to be sent in the host computer's memory to the transmit buffer if it is not full. Both of these operations do require some setup by the CPU, but are automated by the UART and the DMA engine after setup is complete.
16C954
SCC2691 Currently produced by NXP, the 2691 is a single channel UART that also includes a programmable counter/timer. The 2691 has a single byte transmitter holding register and a 4-byte receive FIFO. Maximum standard speed of the 2692 is 115.2 kbit/s. Non-standard speeds are supported.
SCC2692 Currently produced by NXP, these dual UARTs (DUART) are essentially a pair of SCC2691 UARTs in a single package, but with a common counter/timer. Each channel is independently programmable and supports independent transmit and receive data rates. Like the 2691, the 2692 has a single byte transmitter holding register and a 4-byte receive FIFO per channel. Maximum standard speed of both of the 2692's channels is 115.2 kbit/s.

The 26C92 is an upwardly compatible version of the dual channel 2692, with 8-byte transmit and receive FIFOs for improved performance during continuous bi-directional asynchronous transmission (CBAT) on both channels at the maximum standard speed of 230.4 kbit/s.

Both the 2692 and 26C92 may also be operated in RS-422 and RS-485 modes, and can also be programmed to support non-standard data rates. The devices are produced in PDIP-40, PLCC-44 and 44 pin QFP packages, and are readily adaptable to both Motorola and Intel buses. They have also been successfully adapted to the 65C02 and 65C816 buses.

SC26C92
SCC2698B Currently produced by NXP, the 2698 octal UART (OCTART) is essentially four SCC2692 DUARTs in a single package. Specifications are the same as the SCC2692 (not the SCC26C92). The device is produced in PDIP-64 and PLCC-84 packages, and is readily adaptable to both Motorola and Intel buses. The 2698 has also been successfully adapted to the 65C02 and 65C816 buses.
SCC28C94 Currently produced by NXP, the 28C94 quadruple UART (QUART) is functionally similar to a pair of SCC26C92 DUARTs mounted in a common package. Some additional signals are present for interrupt management and the auxiliary input/output pins are arranged differently than those of the 26C92. Otherwise, the programming model for the 28C94 is very similar to that of the 26C92, requiring only minor code changes. The 28C94 supports a maximum standard speed of 230.4 kbit/s, is available in a PLCC-52 package, and is readily adaptable to both Motorola and Intel buses.
SCC28L198 Currently produced by NXP, the 28L198 octal UART (OCTART) is essentially an upscaled enhancement of the SCC28C94 QUART (described above), with eight independent communications channels, as well as an arbitrated interrupt system for efficient processing during periods of intense channel activity. The 28L198 supports a maximum standard speed of 460.8 kbit/s, is available in PLCC-84 and LQFP-100 packages, and is readily adaptable to both Motorola and Intel buses. The 28L198 will operate on 3.3 or 5 volts.
Z85230 Synchronous/Asynchronous modes, 2 ports, DMA. 4-byte buffer to send, 8-byte buffer to receive per channel. SDLC/HDLC modes. 5 Mbit/s in synchronous mode.
Hayes ESP 1 kB buffers, 921.6 kbit/s, 8-ports.[5]

UART in modems[edit]

Modems for personal computers that plug into a motherboard slot must also include the UART function on the card. The original 8250 UART chip shipped with the IBM personal computer had a one character buffer for the receiver and the transmitter each, which meant that communications software performed poorly at speeds above 9600 bits/second, especially if operating under a multitasking system or if handling interrupts from disk controllers. High-speed modems used UARTs that were compatible with the original chip but which included additional FIFO buffers, giving software additional time to respond to incoming data.

A look at the performance requirements at high bit rates shows why the 16, 32, 64 or 128 byte FIFO is a necessity. The Microsoft specification for a DOS system requires that interrupts not be disabled for more than 1 millisecond at a time. Some hard disk drives and video controllers violate this specification. 9600 bit/s will deliver a character approximately every millisecond, so a 1 byte FIFO should be sufficient at this rate on a DOS system which meets the maximum interrupt disable timing. Rates above this may receive a new character before the old one has been fetched, and thus the old character will be lost. This is referred to as an overrun error and results in one or more lost characters.

A 16 byte FIFO allows up to 16 characters to be received before the computer has to service the interrupt. This increases the maximum bit rate the computer can process reliably from 9600 to 153,000 bit/s if it has a 1 millisecond interrupt dead time. A 32 byte FIFO increases the maximum rate to over 300,000 bit/s. A second benefit to having a FIFO is that the computer only has to service about 8 to 12% as many interrupts, allowing more CPU time for updating the screen, or doing other chores. Thus the computer's responses will improve as well.

See also[edit]

References[edit]

  1. ^ Adam Osborne, An Introduction to Microcomputers Volume 1: Basic Concepts, Osborne-McGraw Hill Berkeley California USA, 1980 ISBN 0-931988-34-9 pp. 116-126
  2. ^ "Zilog Product specification Z8440/1/2/4, Z84C40/1/2/3/4. Serial input/output controller".  090529 zilog.com
  3. ^ "FAQ: The 16550A UART & TurboCom drivers 1994".  090529 cs.utk.edu