Jump to content

User:Gastro-en/Electrogastrogram: Difference between revisions

From Wikipedia, the free encyclopedia
Content deleted Content added
Gastro-en (talk | contribs)
No edit summary
Gastro-en (talk | contribs)
No edit summary
Line 29: Line 29:


A bradygastria and tachygastria may be associated with [[nausea]], [[gastroparesis]], [[irritable bowel syndrome]], and [[functional dyspepsia]].<ref>MediLexicon. [http://www.medilexicon.com/medicaldictionary.php Definisions of "Bradygastria" and "Tachygastria"].</ref>
A bradygastria and tachygastria may be associated with [[nausea]], [[gastroparesis]], [[irritable bowel syndrome]], and [[functional dyspepsia]].<ref>MediLexicon. [http://www.medilexicon.com/medicaldictionary.php Definisions of "Bradygastria" and "Tachygastria"].</ref>
===CPT-codes of electrogastrography===
===CPT/HCPCS-codes for electrogastrography===
There are following [[Current Procedural Terminology]] (CPT) codes (maintained by the [[American Medical Association]]) for cutaneous electrogastrography:
There are following [[Current Procedural Terminology]] (CPT) and [[Healthcare Common Procedure Coding System]] (HCPCS) codes (maintained by the [[American Medical Association]]) for cutaneous electrogastrography:<ref>[http://www.gastro.org/user-assets/Documents/12_eDigest/080907/2008%20Proposed%20HOPD%20ASC%20rule%2007-3509.pdf Federal Register. Vol. 72, No. 148 /Thursday, August 2, 2007/ Proposed Rules, 42997].</ref>
{| class="wikitable"
{| class="wikitable"
|-
|-
! CPT-code
! CPT/HCPCS-code
! Procedure
! Procedure
|-
|-

Revision as of 17:38, 4 November 2008

An electrogastrogram (EGG) is a graphic produced by an electrogastrograph, which records the electrical signals that travel through the stomach muscles and control the muscles' contractions. An electrogastroenterogram (or gastroenterogram) is a same procedure, at which write down electric signals not only from a stomach, but also from intestines.

These names are made of different parts: electro, because it is related to electrical activity, gastro, Greek for stomach, entero, Greek for intestines, gram, a Greek root meaning "to write".

An electrogastrogram and a gastroenterogram are similar in principle to an electrocardiogram (ECG) in that sensors on the skin detect electrical signals indicative of muscular activity within. Where the electrocardiogram detects muscular activity in various regions of the heart, the electrogastrogram detects the wave-like contractions of the stomach (peristalsis).

Early studies on electrogastrography have been executed by Walter C. Alvarez in 1921-22.[1]

Physiological basis of electrogastroenterography

Motility of GI tract is results from coordinated contractions of smooth muscle, which in turn derive from two basic patterns of electrical activity across the membranes of smooth muscle cells — slow waves and action potentials.[2] Slow waves are initiated by pacemakers — the interstitial cells of Cajal (ICC). Slow wave frequency varies in the different organs of the GI tract and is characteristic for that organ. They set the maximum frequency at which the muscle can contract:

  • stomach — about 3 waves in a minute,
  • duodenum — about 12 waves in a minute,
  • ileum — about 8 waves in a minute,
  • rectum — about 17 waves in a minute.[3]

The electrical activity of the GI tract can be subdivided into two categories: electrical control activity (ECA) and electrical response activity (ERA). ECA is characterized by regularly recurring electrical potentials, originating in the gastric pacemaker located in the body of stomach. The slow waves are not a direct reason of peristalsis of a GI tract, but a correlation between deviations of slow waves from norm and motility abnormalities however is proved.[4]

Cutaneous electrogastrography

Electrogastrogram can be made from the gastrointestinal mucosa, serosa, or skin surface. The cutaneous electrogastrography and provides an indirect representation of the electrical activity but it is much easier and therefore cutaneous electrogastrography has been used most frequently.

Several EGG signals are recorded from various standardized positions on the abdominal wall and to select the one with the highest amplitude for further analysis. For this purpose usually use three or more Ag-AgCl electrodes.[5] Recordings are made both fasting (usually 30 minutes) and after a meal (usually 60 minutes) with the patient lying quietly. Deviations from the normal frequency may be referred to as bradygastria or tachygastria.

Bradygastria, normogastria and tachygastria

Terms bradygastria and tachygastria are used at the description of deviations of frequency of an electric signal from slow waves are initiated by pacemaker in the stomach from normal frequency of 3 cycles per minute.

A bradygastria is defined, how decreased rate of electrical activity in the stomach, as less than 2 cycles per minute for at least 1 minute.

A tachygastria is defined, how increased rate of electrical activity in the stomach, as more than 4 cycles per minute for at least 1 minute.

A bradygastria and tachygastria may be associated with nausea, gastroparesis, irritable bowel syndrome, and functional dyspepsia.[6]

CPT/HCPCS-codes for electrogastrography

There are following Current Procedural Terminology (CPT) and Healthcare Common Procedure Coding System (HCPCS) codes (maintained by the American Medical Association) for cutaneous electrogastrography:[7]

CPT/HCPCS-code Procedure
91132 Electrogastrography, diagnostic, transcutaneous
91133 Electrogastrography, diagnostic, transcutaneous; with provocative testing

Electrogastroenterography

An electrogastroenterography (EGEG) is based that different organs of a GI tract give different frequency slow wave.

3D human gastroenterogramm. On a vertical axis a spectrum of signal from GI smooth muscle in µV. Frequency ranges from left to right: large intestine, stomach, ileum, jejunum, duodenum
Organ of gastrointestinal tract Investigated range (Hz)
Large intestine 0,01 – 0,03
Stomach 0,03 – 0,07
Ileum 0,07 – 0,13
Jejunum 0,13 – 0,18
Duodenum 0,18 – 0,25

EGEG electrodes are as much as possible removed from a stomach and an intestines — usaually three electrodes are placed on the extremities. It allows to receive stabler and comparable results.


[8]


There ara some lacks limiting an electrogastroenterography use in practice:

  • an absence of a standard technique of performance peripheral electrogastroenterography,
  • an absence of a standard norms of electrophysiological parametres of bioelectric activity GT tract,
  • an impossibility of an estimation of change of motility abnormalities during the concrete moments of time on local sites of GI tract.

Other updatings of electrogastrography

Clinical application of electrogastrography and gastroenterography

Electrogastrography or gastroenterography used when a patient is suspected of having a motility disorder, which can be shown, as recurrent nausea and vomiting, signs that the stomach is not emptying food normally. The clinical use of electrogastrography has been most widely evaluated in patients with gastroparesis and functional dyspepsia.

See also

Sources

References

  1. ^ Alvarez W. C. The electrogastrogram and what it shows. JAMA, 78(15):1116-18, 1922.
  2. ^ Bowen R. Electrophysiology of Gastrointestinal Smooth Muscle. November 23, 1996. Accessed February 12, 2008. http://www.vivo.colostate.edu/hbooks/pathphys/digestion/basics/slowwaves.html
  3. ^ Ginzburg G. V., Costoff A. Gastrointestinal Physiology. Gastrointestinal Motility. Ch. 3, p. 5. GI Smooth Muscle Electrophysiology: Slow Waves (Basal Electric Rhythm).
  4. ^ Parkman H.P., Hasler W.L., Barnett J.L., Eaker E.Y. Electrogastrography: a document prepared by the gastric section of the American Motility Society Clinical GI Motility Testing Task Force. Neurogastroenterology and Motility, Volume 15, Number 2, April 2003 , pp. 89-102(14).
  5. ^ Stendal. Ch. Practical Guide to Gastrointestinal Function Testing. Blackwell Science Ltd., 1997, 280 p. ISBN 0-632-04918-9.
  6. ^ MediLexicon. Definisions of "Bradygastria" and "Tachygastria".
  7. ^ Federal Register. Vol. 72, No. 148 /Thursday, August 2, 2007/ Proposed Rules, 42997.
  8. ^ Stupin V. A., et al. Peripheral Electrogastroenterography in Clinical Practice // Лечащий Врач.-2005.-№ 2.-С. 60-62 Template:Ru icon.