In the [[Bell System]], central offices provided this type of service on a dedicated telephone number (102 type Milliwatt line) for remote subscriber line testing. In conjunction, a second line (type 100 line) provided quiet termination (cf. [[loop around]]). Various types of test lines were called "100", "102", "104" etc. because these numbers accessed the test line in [[tandem office]]s in lieu of an area code.{{Citation needed|date=July 2008}}
In the [[Bell System]], central offices provided this type of service on a dedicated telephone number (102 type Milliwatt line) for remote subscriber line testing. In conjunction, a second line (type 100 line) provided quiet termination (cf. [[loop around]]). Various types of test lines were called "100", "102", "104" etc. because these numbers accessed the test line in [[tandem office]]s in lieu of an area code.{{Citation needed|date=July 2008}}


In digital central office installations, the Milliwatt test facility was implemented using a synthesized version of the 1004 Hz signal, see [[digital milliwatt]].
In digital central office installations, the Milliwatt test facility was implemented using a synthesized version of the 1004 [[Hz]] signal, see [[digital milliwatt]].


== References ==
== References ==

Revision as of 11:34, 31 July 2013

A Milliwatt test (Milliwatt line) is a test method or test facility used in telecommunications to measure line quality and transmission loss between stations or points in an analog telephone system.

The test consists of transmitting an analog sinusoidal signal at the frequency of 1004 Hz with the power level of 0 (zero) dBm. By definition, this is the equivalent of a continuous power dissipation of 1 mW (milliWatt), i.e., the power consumed if a voltage of 0.775 V(RMS) is applied to a telephone line with 600 Ohm nominal impedance.[1]

In the Bell System, central offices provided this type of service on a dedicated telephone number (102 type Milliwatt line) for remote subscriber line testing. In conjunction, a second line (type 100 line) provided quiet termination (cf. loop around). Various types of test lines were called "100", "102", "104" etc. because these numbers accessed the test line in tandem offices in lieu of an area code.[citation needed]

In digital central office installations, the Milliwatt test facility was implemented using a synthesized version of the 1004 Hz signal, see digital milliwatt.

References

  1. ^ H.A. Quinn, et al., 'A New Standard Volume Indicator and Reference Level', Proceedings of the Institute of Radio Engineers, Volume 28 (1940)