Jump to content

Search results

View (previous 20 | ) (20 | 50 | 100 | 250 | 500)
  • Thumbnail for Scintillation counter
    A scintillation counter is an instrument for detecting and measuring ionizing radiation by using the excitation effect of incident radiation on a scintillating...
    14 KB (1,598 words) - 11:57, 11 July 2024
  • Thumbnail for Proportional counter
    plot shows the proportional counter operating voltage region for a co-axial cylinder arrangement. In a proportional counter the fill gas of the chamber...
    11 KB (1,487 words) - 17:26, 7 February 2024
  • Thumbnail for BeppoSAX
    Medium Energy Concentrator Spectrometer (MECS) High Pressure Gas Scintillation Proportional Counter (HPGSPC) Phoswich Detector System (PDS) Wide Field Camera...
    16 KB (1,602 words) - 21:43, 25 April 2024
  • Thumbnail for Geiger counter
    β-particles or provision of particle energy information, scintillation counters or proportional counters should be used. Those instrument types are manufactured...
    23 KB (2,860 words) - 06:42, 6 July 2024
  • Thumbnail for Scintillator
    wavelength of the emitted optical photon. A scintillation detector or scintillation counter is obtained when a scintillator is coupled to an electronic light sensor...
    68 KB (8,016 words) - 15:13, 19 August 2024
  • A wire chamber or multi-wire proportional chamber is a type of proportional counter that detects charged particles and photons and can give positional...
    12 KB (1,336 words) - 22:13, 29 July 2024
  • Thumbnail for High-energy replicated optics
    geometry. The proving flight, at least, used a high-pressure gas scintillation proportional counter with relatively low spatial resolution. High energy X-ray...
    1 KB (107 words) - 15:17, 6 April 2024
  • Thumbnail for Neutron detection
    into the proportional counter. Scintillation neutron detectors include liquid organic scintillators, crystals, plastics, glass and scintillation fibers...
    66 KB (8,368 words) - 22:40, 15 September 2024
  • Thumbnail for History of X-ray astronomy
    sources and their temporal changes. The instrument was a gas scintillation proportional counter (GSPC) with ~ 180 cm2 area and energy resolution of 9% at...
    55 KB (7,174 words) - 21:14, 13 May 2024
  • event is converted to light by even the most efficient scintillation cocktails. Proportional counters and end-window Geiger-Muller tubes have a very high...
    4 KB (494 words) - 12:36, 8 August 2020
  • with a thesis entitled "The Development of an Imaging Gas Scintillation Proportional Counter for Use in X-ray Astronomy." He received tenure from Columbia...
    7 KB (727 words) - 18:24, 3 October 2023
  • Thumbnail for Gamma spectroscopy
    needed] (or, in a scintillation counter, the emitted photons using a photomultiplier). The voltage of the signal produced is proportional to the energy of...
    27 KB (3,329 words) - 18:30, 3 July 2024
  • Thumbnail for X-ray telescope
    principle as the Geiger-Müller counter, but uses a lower operating voltage. All X-ray proportional counters consist of a windowed gas cell. Often this cell is...
    26 KB (3,140 words) - 18:38, 22 June 2024
  • Thumbnail for X-ray fluorescence
    detector: gas flow proportional counters sealed gas detectors scintillation counters semiconductor detectors Gas flow proportional counters are used mainly...
    46 KB (5,717 words) - 18:17, 7 September 2024
  • detectors Neutron detection Particle detector Proportional counter Scintillator Scintillation counter Semiconductor detector Thermoluminescent dosimeter...
    12 KB (1,021 words) - 04:16, 7 March 2024
  • a pulse output as in the cases of the Geiger–Müller tube or the proportional counter. Referring to the accompanying ion-pair collection graph, it can...
    20 KB (2,552 words) - 00:51, 15 May 2024
  • Thumbnail for Dosimeter
    Comparison of dosimeters Geiger counter Ionisation chamber Operational instruments of the Royal Observer Corps Scintillation counter "Archived copy" (PDF). Archived...
    12 KB (1,521 words) - 16:27, 30 March 2024
  • predicted that the number of scintillations per minute s that will be observed at a given angle Φ should be proportional to:: 11  cosec4⁠Φ/2⁠ thickness...
    85 KB (10,885 words) - 19:49, 15 September 2024
  • Thumbnail for Radioactive contamination
    normally by Geiger counter, scintillation counter or proportional counter. Proportional counters and dual phosphor scintillation counters can discriminate...
    35 KB (4,072 words) - 08:44, 16 July 2024
  • Thumbnail for List of measuring instruments
    counter Ionisation chamber Microchannel plate detector Photographic plate Photostimulable phosphor plate Proportional counter Scintillation counter,...
    45 KB (3,620 words) - 14:33, 29 August 2024
View (previous 20 | ) (20 | 50 | 100 | 250 | 500)