Jump to content

2,2-Dichloro-1,1,1-trifluoroethane

From Wikipedia, the free encyclopedia

This is an old revision of this page, as edited by Pahazzard (talk | contribs) at 22:04, 3 December 2015 (top: link). The present address (URL) is a permanent link to this revision, which may differ significantly from the current revision.

2,2-Dichloro-1,1,1-trifluoroethane[1]
Skeletal formula of 2,2-dichloro-1,1,1-trifluoroethane
Space-filling model of the 2,2-dichloro-1,1,1-trifluoroethane molecule
Names
IUPAC name
2,2-Dichloro-1,1,1-trifluoroethane
Other names
1,1,1-Trifluoro-2,2-dichloroethane, Dichlorotrifluoromethylmethane, Dichlorotrifluoroethane, Freon 123, HCFC-123, R 123
Identifiers
3D model (JSmol)
ChemSpider
ECHA InfoCard 100.005.629 Edit this at Wikidata
EC Number
  • 206-190-3
RTECS number
  • KI1108000
  • InChI=1S/C2HCl2F3/c3-1(4)2(5,6)7/h1H checkY
    Key: OHMHBGPWCHTMQE-UHFFFAOYSA-N checkY
  • InChI=1/C2HCl2F3/c3-1(4)2(5,6)7/h1H
    Key: OHMHBGPWCHTMQE-UHFFFAOYAP
  • ClC(Cl)C(F)(F)F
Properties
C2HCl2F3
Molar mass 152.93 g/mol
Appearance Colorless liquid
Density 1.4638 g/cm3
Melting point −107 °C (−161 °F; 166 K)
Boiling point 27.82 °C (82.08 °F; 300.97 K)
0.39%
Vapor pressure 89.3 kPa
1.3392
Hazards
NFPA 704 (fire diamond)
NFPA 704 four-colored diamondHealth 1: Exposure would cause irritation but only minor residual injury. E.g. turpentineFlammability 0: Will not burn. E.g. waterInstability 0: Normally stable, even under fire exposure conditions, and is not reactive with water. E.g. liquid nitrogenSpecial hazards (white): no code
1
0
0
Except where otherwise noted, data are given for materials in their standard state (at 25 °C [77 °F], 100 kPa).
checkY verify (what is checkY☒N ?)

2,2-Dichloro-1,1,1-trifluoroethane or HCFC-123 is considered as an alternative to CFC-11 in low pressure refrigeration/HVAC systems, and should not be used in foam blowing processes or solvent applications.

Its ozone depletion potential is ODP = 0.012, and global warming potential is GWP = 76. HCFC-123 will eventually be phased out under the current schedule of the Montreal Protocol, but can continue to be used in new HVAC equipment until 2020 in developed countries, and will still be produced for service use of HVAC equipment until 2030. Developing countries can use in new equipment until 2030, and can be produced for use in service until 2040.

HCFC-123 is used in large tonnage centrifugal chiller applications, and is the most efficient refrigerant currently in use in the marketplace for HVAC applications. HCFC-123 is also used as a testing agent for bypass leakage of carbon adsorbers in gas filtration systems, and as the primary chemical in Halotron I fire-extinguishing agent.[2]


Storage tanks carrying HCFC-123 should be a light grey.

Isomers are 1,2-dichloro-1,1,2-trifluoroethane (R-123a) with CAS 354-23-4 and 1,1-dichloro-1,2,2-trifluoroethane (R-123b) with CAS 812-04-4.