Jump to content

Eight-point algorithm

From Wikipedia, the free encyclopedia

This is an old revision of this page, as edited by BG19bot (talk | contribs) at 06:25, 18 February 2016 (v1.38b - WP:WCW project (Link equal to linktext)). The present address (URL) is a permanent link to this revision, which may differ significantly from the current revision.

The eight-point algorithm is an algorithm used in computer vision to estimate the essential matrix or the fundamental matrix related to a stereo camera pair from a set of corresponding image points. It was introduced by Christopher Longuet-Higgins in 1981 for the case of the essential matrix. In theory, this algorithm can be used also for the fundamental matrix, but in practice the normalized eight-point algorithm, described by Richard Hartley in 1997, is better suited for this case.

The algorithm's name derives from the fact that it estimates the essential matrix or the fundamental matrix from a set of eight (or more) corresponding image points. However, variations of the algorithm can be used for fewer than eight points.

Coplanarity constraint

Example of epipolar geometry. Two cameras, with their respective centers of projection points OL and OR, observe a point P. The projection of P onto each of the image planes is denoted pL and pR. Points EL and ER are the epipoles.

One may express the epipolar geometry of two cameras and a point in space with an algebraic equation. Observe that, no matter where the point is in space, the vectors , and belong to the same plane. Call the coordinates of point in the left eye's reference frame and call the coordinates of in the right eye's reference frame and call the rotation and translation between the two reference frames s.t. is the relationship between the coordinates of in the two reference frames. The following equation always equals to zero because the vector generated from is orthogonal to both and  :

Because , we get

.

Replacing with , we get

Observe that may be thought of as a matrix; Longuet-Higgins used the symbol to denote it. The product is often called essential matrix and denoted with .

The vectors are parallel to the vectors and therefore the coplanarity constraint holds if we substitute these vectors. If we call the coordinates of the projections of onto the left and right image planes, then the coplanarity constraint may be written as

The basic algorithm

The basic eight-point algorithm is here described for the case of estimating the essential matrix . It consists of three steps. First, it formulates a homogeneous linear equation, where the solution is directly related to , and then solves the equation, taking into account that it may not have an exact solution. Finally, the internal constraints of the resulting matrix are managed. The first step is described in Longuet-Higgins' paper, the second and third steps are standard approaches in estimation theory.

The constraint defined by the essential matrix is

for corresponding image points represented in normalized image coordinates . The problem which the algorithm solves is to determine for a set of matching image points. In practice, the image coordinates of the image points are affected by noise and the solution may also be over-determined which means that it may not be possible to find which satisfies the above constraint exactly for all points. This issue is addressed in the second step of the algorithm.

Step 1: Formulating a homogeneous linear equation

With

  and     and  

the constraint can also be rewritten as

or

where

  and  

that is, represents the essential matrix in the form of a 9-dimensional vector and this vector must be orthogonal to the vector which can be seen as a vector representation of the matrix .

Each pair of corresponding image points produces a vector . Given a set of 3D points this corresponds to a set of vectors and all of them must satisfy

for the vector . Given sufficiently many (at least eight) linearly independent vectors it is possible to determine in a straightforward way. Collect all vectors as the columns of a matrix and it must then be the case that

This means that is the solution to a homogeneous linear equation.

Step 2: Solving the equation

A standard approach to solving this equation implies that is a left singular vector of corresponding to a singular value that equals zero. Provided that at least eight linearly independent vectors are used to construct it follows that this singular vector is unique (disregarding scalar multiplication) and, consequently, and then can be determined.

In the case that more than eight corresponding points are used to construct it is possible that it does not have any singular value equal to zero. This case occurs in practice when the image coordinates are affected by various types of noise. A common approach to deal with this situation is to describe it as a total least squares problem; find which minimizes

when . The solution is to choose as the left singular vector corresponding to the smallest singular value of . A reordering of this back into a matrix gives the result of this step, here referred to as .

Step 3: Enforcing the internal constraint

Another consequence of dealing with noisy image coordinates is that the resulting matrix may not satisfy the internal constraint of the essential matrix, that is, two of its singular values are equal and nonzero and the other is zero. Depending on the application, smaller or larger deviations from the internal constraint may or may not be a problem. If it is critical that the estimated matrix satisfies the internal constraints, this can be accomplished by finding the matrix of rank 2 which minimizes

where is the resulting matrix from Step 2 and the Frobenius matrix norm is used. The solution to the problem is given by first computing a singular value decomposition of :

where are orthogonal matrices and is a diagonal matrix which contains the singular values of . In the ideal case, one of the diagonal elements of should be zero, or at least small compared to the other two which should be equal. In any case, set

where are the two larger singular values in . Finally, is given by

The matrix is the resulting estimate of the essential matrix provided by the algorithm.

Determining R and t from E

This topic is covered in the page on the Essential matrix (section on determining R and t from E).

The normalized eight-point algorithm

The basic eight-point algorithm can in principle be used also for estimating the fundamental matrix . The defining constraint for is

where are the homogeneous representations of corresponding image coordinates (not necessary normalized). This means that it is possible to form a matrix in a similar way as for the essential matrix and solve the equation

for which is a reshaped version of . By following the procedure outlined above, it is then possible to determine from a set of eight matching points. In practice, however, the resulting fundamental matrix may not be useful for determining epipolar constraints.

The problem

The problem is that the resulting often is ill-conditioned. In theory, should have one singular value equal to zero and the rest are non-zero. In practice, however, some of the non-zero singular values can become small relative to the larger ones. If more than eight corresponding points are used to construct , where the coordinates are only approximately correct, there may not be a well-defined singular value which can be identified as approximately zero. Consequently, the solution of the homogeneous linear system of equations may not be sufficiently accurate to be useful.

What's causing the problem

Hartley addressed this estimation problem in his 1997 article. His analysis of the problem shows that the problem is caused by the poor distribution of the homogeneous image coordinates in their space, . A typical homogeneous representation of the 2D image coordinate is

where both lie in the range 0 to 1000-2000 for a modern digital camera. This means that the first two coordinates in vary over a much larger range than the third coordinate. Furthermore, if the image points which are used to construct lie in a relatively small region of the image, for example at , again the vector points in more or less the same direction for all points. As a consequence, will have one large singular value and the remaining are small.

How it can be solved

As a solution to this problem, Hartley proposed that the coordinate system of each of the two images should be transformed, independently, into a new coordinate system according to the following principle.

  • The origin of the new coordinate system should be centered (have its origin) at the centroid (center of gravity) of the image points. This is accomplished by a translation of the original origin to the new one.
  • After the translation the coordinates are uniformly scaled so that the mean distance from the origin to a point equals .

This principle results, normally, in a distinct coordinate transformation for each of the two images. As a result, new homogeneous image coordinates are given by

where are the transformations (translation and scaling) from the old to the new normalized image coordinates. This normalization is only dependent on the image points which are used in a single image and is, in general, distinct from normalized image coordinates produced by a normalized camera.

The epipolar constraint based on the fundamental matrix can now be rewritten as

where . This means that it is possible to use the normalized homogeneous image coordinates to estimate the transformed fundamental matrix using the basic eight-point algorithm described above.

The purpose of the normalization transformations is that the matrix , constructed from the normalized image coordinates, in general has a better condition number than has. This means that the solution is more well-defined as a solution of the homogeneous equation than is relative to . Once has been determined and reshaped into the latter can be de-normalized to give according to

In general, this estimate of the fundamental matrix is a better one than would have been obtained by estimating from the un-normalized coordinates.

Using fewer than eight points

Each point pair contributes with one constraining equation on the element in . Since has five degrees of freedom it should therefore be sufficient with only five point pairs to determine . Though possible from a theoretical point of view, the practical implementation of this is not straightforward and relies on solving various non-linear equations.

References

  • Richard I. Hartley (June 1997). "In Defense of the Eight-Point Algorithm". IEEE Transaction on Pattern Recognition and Machine Intelligence. 19 (6): 580–593. doi:10.1109/34.601246.
  • Richard Hartley and Andrew Zisserman (2003). Multiple View Geometry in computer vision. Cambridge University Press. ISBN 978-0-521-54051-3.
  • H. Christopher Longuet-Higgins (September 1981). "A computer algorithm for reconstructing a scene from two projections". Nature. 293 (5828): 133–135. doi:10.1038/293133a0.