Jump to content

Supporting electrolyte

From Wikipedia, the free encyclopedia
(Redirected from Inert electrolyte)

A supporting electrolyte, in electrochemistry, according to an IUPAC definition,[1] is an electrolyte containing chemical species that are not electroactive (within the range of potentials used) and which has an ionic strength and conductivity much larger than those due to the electroactive species added to the electrolyte. Supporting electrolyte is also sometimes referred to as background electrolyte, inert electrolyte, or inactive electrolyte.

Supporting electrolytes are widely used in electrochemical measurements when control of electrode potentials is required. This is done to increase the conductivity of the solution (to practically eliminate the so-called IR drop, or ohmic potential drop from Ohm's law: V = IR), to eliminate the transport of electroactive species by ion migration in the electric field, to maintain constant ionic strength, to maintain constant pH, etc.[2]

Required properties

[edit]

To properly fulfil its functions, a supporting electrolyte must meet the following criteria:

– no precipitation reaction, or formation of colloidal suspension,
– no formation of complex, so, it is a poor ligand and a weak Lewis base,
– no undesirable redox reaction, so, it is not a redox-active species, or the redox reaction is kinetically strongly hindered,
– no undesirable modification of the pH of the studied solution,
– no loss in the gas phase,
– … .

Commonly used background electrolytes

[edit]

Sodium perchlorate (NaClO4) is often used as a background electrolyte because of its convenient properties to fulfil this function. It is a highly soluble salt (2096 g/L at 25 °C) allowing to increase the ionic strength of a solution up to 8 M. It is not a complexing ligand, thus it does not interfere in complexation studies. Quite surprisingly, it is also a redox-insensitive, or a redox-inactive, species, and does not interfere in redox reaction. Contra-intuitively, although perchlorate is well known to be a strong oxidizer in propulsive powder at high temperature and is used in rocket propellant and fireworks, when the perchlorate anion is dissolved in aqueous solution, it does not exhibit any oxidizing power.

Astonishingly, sodium perchlorate can be used with solutions containing ferrous ions (Fe2+) although these ions are quite sensitive to oxidation by dissolved oxygen if the solution is exposed to the air.

The reason is not to be searched in its thermodynamic stability because when in contact with a reducer at high temperature, it violently reacts to dissipate a large quantity of energy in a vigorous exothermic reaction. The reason of its redox inertness when dissolved in water is due to severe kinetic limitations to abiotically accept electrons, even if the oxidation state of the central chlorine atom in this tetrahedral oxyanion is +7. In term of chemical kinetics, perchlorate is a non-labile species because of a high activation energy hindering its redox reactivity. This can be partially explained by the shielding of the central chlorine (+7) atom by the four surrounding oxygen atoms. The ionic radius of the perchlorate anion is about the same as this of the iodide anion. Its molecular orbital configuration likely also plays a role in its great inertness in aqueous solution, and as a rule of thumb, most oxyanions with a central atom in its highest oxidation state are weaker oxidizers than other oxyanions of the same series with a lower oxidation state. Hypochorite (ClO) and chlorate (ClO3) anions although being able to accept less electrons than perchlorate (ClO4) are much stronger oxidizers in aqueous solution because of less kinetic limitations.

See also

[edit]

References

[edit]
  1. ^ IUPAC, Compendium of Chemical Terminology, 2nd ed. (the "Gold Book") (1997). Online corrected version: (2006–) "supporting electrolyte". doi:10.1351/goldbook.S06149
  2. ^ Joseph Wang, "Analytical Electrochemistry", 3rd edition, Wiley VCH. 2006, ISBN 978-0-471-67879-3, p. 118.

Further reading

[edit]
  • Cotton, F.A., and G. Wilkinson. (1988). Advanced Inorganic Chemistry, 5th ed. Wiley, New York, NY. p. 668.
  • Cotton, F.A., G. Wilkinson, and P.L. Gaus. (1987). Basic Inorganic Chemistry, 2nd ed. Wiley, New York, NY. p. 219.
  • Katsounaros, I.; Kyriacou, G. (2007). "Influence of the concentration and the nature of the supporting electrolyte on the electrochemical reduction of nitrate on tin cathode". Electrochimica Acta. 52 (23): 6412–6420. doi:10.1016/j.electacta.2007.04.050. ISSN 0013-4686.
  • Kok, W. (2000). The Background Electrolyte. In: Capillary Electrophoresis: Instrumentation and Operation. Chromatographia CE-Series, Vol 4. Vieweg+Teubner Verlag, Wiesbaden. Print ISBN 978-3-322-83135-4. https://doi.org/10.1007/978-3-322-83133-0_7
  • Kowacz, M.; Putnis, A. (2008). "The effect of specific background electrolytes on water structure and solute hydration: Consequences for crystal dissolution and growth". Geochimica et Cosmochimica Acta. 72 (18): 4476–4487. doi:10.1016/j.gca.2008.07.005. ISSN 0016-7037.
  • Ujvari, M., & Lang, G. (2011). On the stability of perchlorate ions against reductive attacks in electrochemical systems and in the environment. Journal of Electrochemical Science and Engineering, 1(1), 1–26. Available in open access at: https://doi.org/10.5599/jese.2011.0003