PL-6
PL-6 was a system programming language based on PL/I. PL-6 was developed by Honeywell, Inc. in the late 1970s as part of the project to develop the CP-6 operating system.
Description
Data types
Declaration attribute |
Description |
---|---|
SBIN(n) | Signed binary integer of n bits. If (n) is not specified, 36 bits is the default. Alternatively "SBIN WORD", "SBIN HALF", or "SBIN BYTE" specifies 36, 18, or 9 bits respectively. |
UBIN(n) | Unsigned binary integer of n bits. Otherwise the same as SBIN. |
CHAR(c) | Fixed-length character string of length c characters. |
BIT(b) | Fixed-length bit string of length b bits. |
PTR | A memory address. |
PL-6 has no provision for floating point data.
Aggregates
Arrays were one dimensional and zero-based, with the zero specified explicitly. For example, DCL x (0:4) SBIN;
declares an array of five signed 36-bit integers. The elements were numbered x(0), x(1),...,x(4).
Structures were also supported. For example:
DCL 1 struct,
2 a,
3 b CHAR(3),
3 * CHAR(1),
2 c CHAR(4);
declares a structure named struct consisting to two elements: a minor structure a consisting of a three-character field b and an unnamed one-character element ("*" indicates the element is unnamed), and a four-character element c.
The top level of the structure had to be 1, and the remaining levels 2–10, if used, had to be specified in order with no levels skipped.
References
This section is empty. You can help by adding to it. (September 2014) |
External links
- Honeywell, Inc. (June 1988). CP-6 Introduction to PL-6 (PDF). Retrieved Sep 3, 2014.