This is an old revision of this page, as edited by AquaDTRS (talk | contribs) at 19:16, 20 July 2020 (removed Category:Fusion power; added Category:Magnetic confinement fusion devices using HotCat). The present address (URL) is a permanent link to this revision, which may differ significantly from the current revision.

The Gas Dynamic Trap is a magnetic mirror machine being operated at the Budker Institute of Nuclear Physics in Akademgorodok, Russia.

Technical Specifications

Dimensions The plasma inside the machine fills a cylinder of space, 7 meters long and 28 centimeters in diameter.[1] The magnetic field varies along this tube. In the center the field is low; reaching (at most) 0.35 Teslas. The field rises to as high as 15 Teslas at the ends.[1] This change in the strength is needed to reflect the particles and get them internally trapped (see: the magnetic mirror effect).

Heating The plasma is heated using two methods, simultaneously. The first is neutral beam injection, where a hot (25 keV), neutral beam of material is shot into the machine at a rate of 5 megawatts.[1] The second is Electron Cyclotron Resonance Heating which is where electromagnetic waves are used to heat a plasma, analogous to microwaving it.

Performance As of 2016, the machine had achieved a plasma trapping beta of 0.6 for 5 milliseconds.[2] It had reached an electron temperature of 1 keV using the method of Electron cyclotron resonance heating. It had reached an ion density of 1×1020 ions/m3.[1] The machine loses material out of the ends of the mirror [3] but material is replenished at such a rate as to maintain a density inside the machine.[3]

Diagnostics

During any given experiment, operators can choose from at least 15 fusion diagnostics to measure the machines' behavior:[2]

  1. Thomson Scattering
  2. Motional Stark Effect
  3. CX Energy Analysis (2)
  4. Rutherford Ion Scattering
  5. Ion End Loss Analyzer
  6. Microwave Interferometer
  7. Dispersion Interferometer
  8. Diamagnetic Loops
  9. Langmuir Probes
  10. Pyro electric Detectors
  11. RF Probes
  12. Beam Dump Calorimeters
  13. NBI Sec. Electron Detectors
  14. Neutron Detectors
  15. Thermonuclear Proton Detectors

Pictures of the GDT

References

  1. ^ a b c d Simonen, Thomas C. (2015-09-25). "Three Game Changing Discoveries: A Simpler Fusion Concept?". Journal of Fusion Energy. 35 (1). Springer Science and Business Media LLC: 63–68. doi:10.1007/s10894-015-0017-2. ISSN 0164-0313.
  2. ^ a b Gas Dynamic Trap (GDT). Experiments with Electron Heating. Budker Institute of Nuclear Physics, Novosibirsk State University. Siberian Branch, Russia, 2012, Thomas Simonen
  3. ^ a b Ivanov, A A; Prikhodko, V V (2013-05-14). "Gas-dynamic trap: an overview of the concept and experimental results". Plasma Physics and Controlled Fusion. 55 (6). IOP Publishing: 063001. doi:10.1088/0741-3335/55/6/063001. ISSN 0741-3335.
  4. ^ Bagryansky, P. A.; Shalashov, A. G.; Gospodchikov, E. D.; Lizunov, A. A.; Maximov, V. V.; et al. (2015-05-18). "Threefold Increase of the Bulk Electron Temperature of Plasma Discharges in a Magnetic Mirror Device". Physical Review Letters. 114 (20). American Physical Society (APS): 205001. doi:10.1103/physrevlett.114.205001. ISSN 0031-9007.