Imaichi Dam

Coordinates: 36°49′31″N 139°39′58″E / 36.82528°N 139.66611°E / 36.82528; 139.66611
From Wikipedia, the free encyclopedia

This is an old revision of this page, as edited by Lklundin (talk | contribs) at 15:33, 22 March 2017 (See also: {{stack|{{Portal|Japan|Water|Renewable energy}}}}). The present address (URL) is a permanent link to this revision, which may differ significantly from the current revision.

Imaichi Dam
Imaichi Dam is located in Japan
Imaichi Dam
Location of Imaichi Dam in Japan
CountryJapan
LocationNikkō, Tochigi Prefecture
Coordinates36°49′31″N 139°39′58″E / 36.82528°N 139.66611°E / 36.82528; 139.66611
StatusOperational
Construction began1979
Opening date1986
Owner(s)TEPCO
Dam and spillways
Type of damGravity, concrete
ImpoundsTogawa River
Height75.5 m (248 ft)
Length177 m (581 ft)
Elevation at crest551 m (1,808 ft)
Dam volume192,000 m3 (251,127 cu yd)
Spillway capacity1,620 m3/s (57,210 cu ft/s)
Reservoir
Total capacity9,100,000 m3 (7,377 acre⋅ft)
Active capacity6,200,000 m3 (5,026 acre⋅ft)
Catchment area14.8 km2 (6 sq mi)
Surface area380 m2 (0 acres)
Normal elevation548.5 m (1,800 ft)
Power Station
Commission date1988
Hydraulic head524 m (1,719 ft)
Turbines3 x 350 MW (470,000 hp) Francis pump turbines
Installed capacity1,050 MW (1,410,000 hp)

The Imaichi Dam (今市ダム) is a concrete gravity dam on the Togawa River located 4 kilometres (2.5 mi) west of Nikkō in Tochigi Prefecture, Japan. The dam serves as the lower reservoir for the 1,050 megawatts (1,410,000 hp) Imaichi Pumped Storage Power Station, while the Kuriyama Dam forms the upper. It is owned by TEPCO and was constructed between 1979 and 1986, with the first generator commissioned in 1988. Its reservoir can store 9,100,000 cubic metres (7,400 acre⋅ft) of water. Of that storage volume, 6,200,000 cubic metres (5,000 acre⋅ft) can be used for power generation.

Imaichi Pumped Storage Power Station

The power plant operates using the pumped storage hydroelectric method. During periods of high electricity demand, water is sent from the upper Kuriyama Reservoir to the power plant which contains 3 x 350 megawatts (470,000 hp) Francis pump turbines. Water discharged from the power plant then enters the Imaichi Reservoir. When demand is low, the pump-generators reverse mode and pump water from the lower reservoir back up to the upper. The process repeats as needed.[1][2]

See also

References

  1. ^ "Tokyo Electric Power Station Imaichi" (in Japanese). Suiryoku.com. Retrieved 19 January 2012.
  2. ^ Engineers, prepared by Task Committee on Pumped Storage of the Committee on Hydropower of the Energy Division of the American Society of Civil (1996). Hydroelectric pumped storage technology : international experience. New York, NY: American Soc. of Civil Engineers. pp. 2.2 1–5. ISBN 0-7844-0144-6.