'''Blow-Fill Seal''', also spelled as '''Blow/Fill/Seal''', in this article abbreviated as '''BFS''', is an automated manufacturing process by which plastic containers, such as bottles or ampoules are, in a continuous operation, blow-formed, filled, and sealed.<ref name="Niazi_2020_33" /><ref name="Steinbon_2005_261" /> It takes place in a sterile, enclosed area inside a machine, without human intervention, and thus can be used to [[aseptic processing|aseptically manufacture]] sterile pharmaceutical or non-pharamceutical liquid/semiliquid unit-dosage forms.<ref name="Sinclair_1995" /><ref name="Bradley_1991" /> BFS is an advanced aseptic processing technology that is typically used for filling and packaging of certain sterile liquid formulations like [[Eye drop|liquid ophtalmics]], [[inhalational anesthetic]]s, or [[Therapeutic irrigation|lavaging agents]], but can also be used for [[Injection (medicine)|injectables]],<ref name="Niazi_2020_33" /> [[Route_of_administration#Parenteral|parenterals]],<ref name="Flickinger_2013_703" /> and several other liquid or semiliquid medications,<ref name="Thielen_2021_139" /> with fill volumes ranging from 0.1...1000&nbsp;cm³.<ref name="Gibson_2009_339" /><ref name="Spalding_2018_1103" /><ref name="Downey_2016" /> Compared against traditional glass ampoules, BFS ampoules are inexpensive, lightweight, and shatterproof.<ref name="Amin_2010" /> Important BFS system suppliers are [[Weiler Engineering]], [[Rommelag]] (Bottelpack),<ref name="Dean_2000_438" /> and [[Brevetti Angela]].
[[File:Ögondroppar2.jpg|thumb|Eye drops BFS packaged for single use, sterile, without preservatives]]
'''Blow-Fill-Seal''' (BFS) technology is a manufacturing technique used to produce small (0.1mL) and large volume (over 500mL) liquid-filled containers. Originally developed in [[Europe]] in the 1930s, it was introduced in the [[United States]] in the 1960s, but over the last 20 years it has become more prevalent within the [[pharmaceutical industry]] and is now widely considered to be the superior form of [[aseptic processing]] by various medicine regulatory agencies including the [[U.S. Food and Drug Administration]] (FDA) in the packaging of pharmaceutical and healthcare products.


== History ==
The basic concept of BFS is that a container is formed, filled, and sealed in a continuous process without human intervention, in a [[Sterilization (microbiology)|sterile]] enclosed area inside a machine. Thus this technology can be used to [[aseptic]]ally manufacture sterile pharmaceutical liquid dosage forms.<ref> {{cite journal

BFS was developed in the early 1960s<ref name="Swarbrick_2001_1" /> at Rommelag.<ref name="Oschmann_Schubert_1999_17" /> In 1963, Gerhard Hansen applied for a patent on the BFS process.<ref name="Hansen_1963" /> Originally, it was used for packaging of non-sterile products, such as non-sterile medical devices, food, and cosmetics.<ref name="Amin_2010" /> In the early 1970s, Rommelag's Bottelpack system was first used for packing large volume pharmaceutical solutions.<ref name="Oschmann_Schubert_1999_17" /> By the late 1980s, BFS had been well-established in the packaging industry, especially for packaging pharmaceutical and healthcare products.<ref name="EPN_1989" /> During the 1980s and 1990s, BFS came into use for the now common small volume unit-dosage forms.<ref name="Oschmann_Schubert_1999_17" /> Since the early 2000s, BFS has been emerging as the preferred packaging process for parenteral products.<ref name="Gibson_2009_339" />

== BFS process ==

The BFS process functions similarly to conventional extrusion blow molding, and takes place within a BFS machine.<ref name="Thielen_2021_139" /> First, a plastic polymer resin is heated to >160 °C and compressed to 35&nbsp;MPa,<ref name="Swarbrick_2001_1" /><ref name="Oschmann_Schubert_1999_20" /> allowing it to be extruded in tubular form,<ref name="Niazi_2020_33" /> and be taken over by an open two-part<ref name="Rosato_2004_302" /> mold to form the container. Then, the mold closes which welds the bottom of the container. Simultaneously, the parison above the mold is cut, or the filling needles are placed in the parison head without the parison being cut (rotary BFS type). Next, a filling mandrel with blowing air function is placed in the neck area that seals the container. Sterile compressed air is then introduced through the filling mandrel to inflate and form the container. In the BFS process for smaller ampoules the compressed air system is avoided by using vacuum forming the container instead. After the BFS container has been formed, the desired liquid is filled into the container through the filling mandrel unit. Then, the filling mandrel unit is lifted off, and the head mold hermetically seals the container. Simultaneously, the head contour is formed by vacuum. In the last step, the mold opens and the finished container leaves the mold.<ref name="Thielen_2021_139" />

One process cycle takes a few seconds.<ref name="Swarbrick_2001_1" /> The process speed and thus process output largely depends upon the BFS container size and the BFS machinery dimensioning. For instance, in the early 2000s, Rommelag's 3012, 305, and 4010 M machines had outputs of approximately 4000, 8000, or 20,000 containers per hour.<ref name="Dean_2000_438" /> These machines have been succeeded by the Rommelag 312, 321, 360, 364 and 460 machines with output ranges of up to 35,000 containers per hour.

=== Sterility requirements ===

The BFS processes is an aseptic filling process, which produces sterile products and thus needs to be sterile.<ref name="Oschmann_Schubert_1999_23" /> Aseptic BFS machines must be designed in a way that prevents extraneous contamination.<ref name="Nema_2010_7"/> Thus, rotary-type BFS machines are placed in classified areas same as shuttle-type BFS machines (open parison), which have a cleanroom shroud [[Cleanroom#EU_GMP_classification|grade-A-compliant]] provided with sterilised air and kept under overpressure. Automatic SIP programs are used to sterilise the BFS equipment and this avoids human interventions. Due to automatic start up and filling processes BFS machines require no human interaction during the actual BFS process. However, certain adjustments or interventions need to be carried out by personnel. Both particle and microbiological contamination monitoring are required in a BFS machine environment, as well as routine CIP/SIP processes.<ref name="Swarbrick_2001_2" /> BFS machines are typically fitted with several different sterilising air filtration systems for the buffer air, support parison air and air shroud grade A air (if needed for shuttle machines, e. g. open parison type ones).<ref name="Downey_2016" /> Typically, the air is sterilised by filtration systems that have automatic filter integrity testing installed (i. e. automatic water intrusion or particle testing). The air systems are typically integrated into the SIP cycle of the BFS machine. <ref name="Jornitz_2020_539" />

=== BFS material ===

The materials used in BFS packaging are usually [[polyolefins]], mainly [[polyethylene]] ([[LDPE]]<ref name="Gad_2008_103" /><ref name="das Neves_2014_444" /> or [[HDPE]]),<ref name="Vasile_2005_124" /> and [[polypropylene]] (PP).<ref name="Amin_2012" /><ref name="Denyer_2011_387" /><ref name="Oschmann_Schubert_1999_42" /> These materials are robust and inert to ensure sterility and tightness during the product's shelf life.<ref name="Flickinger_2013_703" /> Diffusion tendencies can be reduced by using virgin polymers, but diffusion cannot be prevented entirely. This is due to the nature of polyolefins and their additives, if present.<ref name="Amin_2012" /> Several polyethylene suppliers have developed special EP or [[Chemical purity|USP]] grade resin for BFS containers. Permeation into BFS containers and water loss may be an issue with some BFS resin. Therefore, in some applications, secondary packaging methods (laminate pouches) are used.<ref name="Spalding_2018_1104" />

== Advantages ==

BFS allows many different container designs, a consistent high process quality, a high process output,<ref name="Gibson_2009_339" /> and is, compared against other packaging processes, inexpensive.<ref name="Denyer_2011_387" /> In addition to that, BFS containers are lighter than glass containers, and shatterproof, which eases their transport.<ref name="Amin_2010" /><ref name="Oschmann_Schubert_1999_81" /> Due to the single-dose nature of BFS containers, they are more convenient to use for patients.<ref name="Pearlman_1996_417" /> BFS technology assures high levels of sterility,<ref name="Groves_1995_364" /><ref name="Swarbrick_2001_10" /><ref name="Gail_2018_602" /> especially compared against conventional filling,<ref name="Sandle_2016_154" /> which is mainly achieved by the absence of human contact/interventions – a major source of contamination.<ref name="Hardee_1998_208" />

== External links ==

*[https://vimeo.com/173339055 bottelpack Blow-Fill-Seal process 3D model visualisation], video, 0:20&nbsp;min

==References==
<references responsive>

<ref name="Denyer_2011_387">{{Citation
| author-link =
| last1 = Denyer
| first1 = Stephen P.
| last2 = Hodges
| first2 = Norman
| last3 = Gorman
| first3 = Sean P.
| last4 = Gilmore
| first4 = Brendan F.
| year =2011
| title = Hugo and Russell’s Pharmaceutical Microbiology
| publisher = Wiley-Blackwell
| location = Chichester
| language = en
| isbn = 9781444330632}}, p. 387</ref>

<ref name="Gail_2018_602">{{Citation
| author-link =
| last1 = Gail
| first1 = Lothar
| last2 = Gommel
| first2 = Udo
| year = 2018
| title = Reinraumtechnik
| edition = 4th
| publisher = Springer
| location = Berlin
| language = de
| isbn = 978-3-662-54914-8}}, p. 602</ref>

<ref name="Groves_1995_364">{{Citation
| author-link =
| last1 = Groves
| first1 = Michael J.
| last2 = Murty
| first2 = Ram
| year = 1995
| title = Aseptic Pharmaceutical Manufacturing II – Applications for the 1990s
| edition =
| publisher = CRC Press
| location = Boca Raton London New York
| language = en
| isbn = 978-0-935184-77-8}}, p. 364</ref>

<ref name="Nema_2010_7">{{Citation
| author-link =
| last1 = Nema
| first1 = Sandeep
| last2 = Ludwig
| first2 = John D.
| edition = 3rd
| year = 2010
| title = Pharmaceutical Dosage Forms: Parental Medications – Volume 3: Regulations, Validation and the Future
| publisher = informa healthcare
| location = New York, London
| language = en
| isbn = }}, p. 7</ref>

<ref name="Rosato_2004_302">{{Citation
| author-link =
| last1 = Rosato
| first1 = Dominick V.
| last2 = Rosato
| first2 = Donald V.
| last3 = Rosato
| first3 = Matthew V.
| year =2005
| title = Plastic Product Material and Process Selection Handbook
| publisher = Elsevier Science & Technology Books
| location =
| language = en
| isbn = 9780080514055}}, p. 302</ref>

<ref name="Gad_2008_103">{{Citation
| author-link =
| last1 = Gad
| first1 = Shayne Cox
| year =2008
| title = Pharmaceutical Manufacturing Handbook – Production and Processes
| publisher = Wiley
| location = Hoboken
| language = en
| isbn = 978-0-470-25958-0}}, p. 103</ref>

<ref name="Dean_2000_438">{{Citation
| author-link =
| last1 = Dean
| first1 = D. A.
| last2 = Evans
| first2 = E. R.
| last3 = Hall
| first3 = I. H.
| year = 2000
| title = Pharmaceutical Packaging Technology
| publisher = Taylor & Francis
| location = London New York
| language = en
| isbn = 0-7484-0440-6}}, p. 438</ref>

<ref name="Sandle_2016_154">{{Citation
| author-link =
| last1 = Sandle
| first1 = Tim
| year = 2016
| title = Pharmaceutical Microbiology – Essentials for Quality Assurance and Quality Control
| edition =
| publisher = Woodhead Publishing Limited
| location = Cambridge
| language = en
| isbn = 978-0-08-100022-9}}, p. 154</ref>

<ref name="Steinbon_2005_261">{{Citation
| author-link =
| last1 = Steinborn
| first1 = Leonhard
| year = 2005
| title = GMP/ISO Quality Audit Manual for Healthcare Manufacturers and Their Suppliers – Volume 2: Regulations, Standards, and Guidelines
| edition = 6th
| publisher = CRC Press
| location = Boca Raton London New York Washington, D.C.
| language = en
| isbn = 0-8493-1847-5}}, p. 261</ref>

<ref name="Spalding_2018_1103">{{Citation
| author-link =
| last1 = Spalding
| first1 = Mark A.
| last2 = Chatterjee
| first2 = Ananda M.
| year = 2018
| title = Handbook of Industrial Polyethylene and Technology
| edition = 1st
| publisher = Scrivener Publishing
| location = Beverly
| language = en
| isbn = 9781119159766}}, p. 1103</ref>

<ref name="Spalding_2018_1104">{{Citation
| author-link =
| last1 = Spalding
| first1 = Mark A.
| last2 = Chatterjee
| first2 = Ananda M.
| year = 2018
| title = Handbook of Industrial Polyethylene and Technology
| edition = 1st
| publisher = Scrivener Publishing
| location = Beverly
| language = en
| isbn = 9781119159766}}, p. 1104</ref>

<ref name="Gibson_2009_339">{{Citation
| title = Pharmaceutical Preformulation and Formulation
| author-link =
| last1 = Gibson
| first1 = Mark
| edition = 2nd
| publisher = informa healthcare
| location = Newy York London
| year = 2009
| language = en
| isbn =978-1-4200-7318-8}}, p. 339</ref>

<ref name="das Neves_2014_444">{{Citation
| title =Mucosal Delivery of Biopharmaceuticals – Biology, Challenges and Strategies
| author-link =
| last1 = das Nevas
| first1 = José
| last2 = Sarmento
| first2 = Bruno
| edition =
| publisher = Springer
| location = New York Heidelberg Dordrecht London
| year = 2014
| language = en
| isbn =978-1-4614-9523-9}}, p. 444</ref>

<ref name="Thielen_2021_139">{{Citation
| title = Extrusion Blow Molding
| author-link =
| last1 = Thielen
| first1 = Michael
| edition =
| publisher = Carl Hanser Verlag
| location =
| year = 2021
| language = en
| isbn =9781569908419}}, p. 139</ref>

<ref name="Nordhauser_1998_281">{{Citation
| title = Sterilization of Drugs and Devices – Technologies for the 2000s
| author-link =
| last1 = Nordhauser
| first1 = Fred M.
| last2 = Olson
| first2 = Wayne P.
| edition =
| publisher = CRC Press
| location = Boca Raton London New York
| year = 1998
| language = en
| isbn =978-1574910605}}, p. 281</ref>

<ref name="Niazi_2020_33">{{Citation
| title = Handbook of Pharmaceutical Manufacturing Formulations – Volume 6: Sterile Products
| author-link =
| last1 = Niazi
| first1 = Sarfaraz K.
| edition = 3rd
| publisher = CRC Press
| location = Boca Raton London New York
| year = 2020
| language = en
| isbn =978-1-138-10383-2}}, p. 33</ref>

<ref name="Jornitz_2020_539">{{Citation
| title = Filtration and Purification in the Biopharmaceutical Industry
| author-link =
| last1 = Jornitz
| first1 = Maik W.
| edition = 3rd
| publisher = CRC Press
| location = Boca Raton London New York
| year = 2020
| language = en
| isbn =978-1-138-05674-9}}, p. 539</ref>

<ref name="Flickinger_2013_703">{{Citation
| title = Downstream Industrial Biotechnology – Recovery and Purification
| author-link =
| last1 = Flickinger
| first1 = Michael C.
| edition =
| publisher = Wiley
| location = Hoboken
| year = 2013
| language = en
| isbn =978-1-118-13124-4}}, p. 703</ref>

<ref name="Vasile_2005_124"> {{Citation
| title = Practical Guide to Polyethylene
| author-link =
| last1 = Vasile
| first1 = Cornelia
| last2 = Pascu
| first2 = Mihaela
| edition =
| publisher = Rapra Technology Limited
| location = Shawbury
| year = 2005
| language = en
| isbn =1-85957-493-9}}, p. 124</ref>

<ref name="Hardee_1998_208">{{Citation
| title = Development and Formulation of Veterinary Dosage Forms – Drugs and the Pharmaceutical Sciences
| author-link =
| last1 = Hardee
| first1 = Gregory E.
| last2 = Baggot
| first2 = J. Desmond
| edition = 2nd
| publisher = Marcel Dekker
| location = New York · Basel · Hong Kong
| year = 1998
| language = en
| isbn =0824798783}}, p. 208</ref>
<ref name="Swarbrick_2001_1">{{Citation
| title = Encyclopedia of Pharmaceutical Technology – Volume 20
| author-link =
| last1 = Swarbrick
| first1 = James
| last2 = Boylan
| first2 = James C.
| edition =
| publisher = Marcel Dekker
| location = New York · Basel
| year = 2001
| language = en
| isbn =9780824728199}}, p. 1</ref>
<ref name="Swarbrick_2001_2">{{Citation
| title = Encyclopedia of Pharmaceutical Technology – Volume 20
| author-link =
| last1 = Swarbrick
| first1 = James
| last2 = Boylan
| first2 = James C.
| edition =
| publisher = Marcel Dekker
| location = New York · Basel
| year = 2001
| language = en
| isbn =9780824728199}}, p. 2</ref>
<ref name="Swarbrick_2001_10">{{Citation
| title = Encyclopedia of Pharmaceutical Technology – Volume 20
| author-link =
| last1 = Swarbrick
| first1 = James
| last2 = Boylan
| first2 = James C.
| edition =
| publisher = Marcel Dekker
| location = New York · Basel
| year = 2001
| language = en
| isbn =9780824728199}}, p. 10</ref>
<ref name="Pearlman_1996_417"> {{Citation
| title = Formulation, Characterization, and Stability of Protein Drugs – Case Histories; Volume 9 of Pharmaceutical Biotechnology
| author-link =
| last1 = Pearlman
| first1 = Rodney
| last2 = Wang
| first2 = Y. John
| edition =
| publisher = kluwer Academic Publishers
| location = New York, Boston, Dordrecht, London, Moscow
| year = 1996
| language = en
| isbn = 0-306-45332-0}}, p. 417</ref>

<ref name="Amin_2010">{{Citation
| title = Sorption of antimicrobial agents in blow-fill-seal packs
| author-link =
| last1 = Amin
| first1 = A.
| last2 = Chauhan
| first2 = S.
| last3 = Dare
| first3 = M.
| last4 = Bansal
| first4 = A. K.
| edition =
| publisher = informa healthcare
| location =
| year = 2012
| language = en
| ISSN = 1083-7450
| DOI = 10.3109/10837450.2010.516438}}</ref>
<ref name="Amin_2012">{{Citation
| title = Interaction of antimicrobial preservatives with blow-fill-seal packs: correlating sorption with solubility parameters
| author-link =
| last1 = Amin
| first1 = A.
| last2 = Sangamwar
| first2 = A.
| last3 = Dare
| first3 = M.
| last4 = Bansal
| first4 = A. K.
| edition =
| publisher = informa healthcare
| location =
| year = 2012
| language = en
| ISSN = 1083-7450
| DOI = 10.3109/10837450.2011.557733}}</ref>

<ref name="Sinclair_1995"> {{cite journal
| last =Sinclair
| last =Sinclair
| first =C S
| first =C S
Line 9: Line 400:
| journal =PDA-Journal of Pharmaceutical Science and Technology
| journal =PDA-Journal of Pharmaceutical Science and Technology
| volume =49
| volume =49
| pages =494–499
| pages =494-499
| date =1995
| date =1995
| pmid =8581461
| url =http://weilerengineering.com/images/downloads/TechnicalPapers/ResearchPapers/Performance%20of%20Blow-Fill-Seal%20Equipment%20Under%20Controlled%20Airborne%20Microbial%20Challenges.pdf
| url =http://weilerengineering.com/images/downloads/TechnicalPapers/ResearchPapers/Performance%20of%20Blow-Fill-Seal%20Equipment%20Under%20Controlled%20Airborne%20Microbial%20Challenges.pdf
| accessdate =24 March 2021}}</ref><ref>{{citation
| accessdate =24 March 2021}}</ref>
<ref name="Bradley_1991">{{citation
| last = Bradley
| last = Bradley
| first =A
| first =A
Line 21: Line 412:
| issue =4
| issue =4
| date =July 1991
| date =July 1991
| pages = 187–194
| pages = 187-194
| pmid =1770413
| url =https://weilerengineering.com/images/downloads/TechnicalPapers/ResearchPapers/Airborne%20Microbial%20Challenges%20of%20Blow-Fill-Seal%20Equipment%20-%20A%20Case%20Study.pdf
| url =https://weilerengineering.com/images/downloads/TechnicalPapers/ResearchPapers/Airborne%20Microbial%20Challenges%20of%20Blow-Fill-Seal%20Equipment%20-%20A%20Case%20Study.pdf
| accessdate = 25 March 2021}}
| accessdate = 25 March 2021}}
</ref>
</ref>


<ref name="Hansen_1963">{{cite patent
The material choice is usually polyethylene or polypropylene with the specific grade matched to the product and process in use. <ref>{{cite book
| country = United Kingdom
| last1 =Oschmann
| number = GB1041548A
| last2 =Schubert
| status =
| title =Blow-Fill-Seal Technology
| title = Improvements relating to blow moulding machines
| publisher =
| pubdate = 1966-09-07
| date =1999
| gdate =
| pages =41–51
| fdate =
| isbn =9783804716209
| pridate =
| url = https://books.google.com/books?id=bD07_ML_x5sC&dq=Blow+fill+seal&pg=PA41
| inventor = Gerhard Hansen
| accessdate =23 Mar 2021
| invent1 =
| invent2 =
| assign1 =
| assign2 =
| class =
| url = https://worldwide.espacenet.com/patent/search?q=pn%3DGB1041548A
}}</ref>
}}</ref>


<ref name="Oschmann_Schubert_1999_17">{{Citation
The process is multi-stepped: first, pharmaceutical-grade plastic resin is vertically heat extruded through a circular throat to form a hanging tube called the [[parison]]. This extruded tube is then enclosed within a two-part mould, and the tube is cut above the mould. The mould is transferred to the filling zone, or sterile filling space, where filling needles ([[mandrel]]s) are lowered and used to inflate the plastic to form the container within the mould. Following the formation of the container, the [[mandrel]] is used to fill the container with liquid. Following filling the mandrels are retracted and a secondary top mould seals the container. All actions take place inside a sterile shrouded chamber inside the machine. The product is then discharged to a non-sterile area for labeling, packaging and distribution.
| title = Blow-Fill-Seal Technology
| author-link =
| last1 = Oschmann
| first1 = R.
| last2 = Schubert
| first2 = O. E.
| edition =
| publisher = Wissenschaftliche Verlagsgesellschaft mbH – CRC Press Inc.
| location = Stuttgart
| year = 1999
| volume = 40
| language = en
| ISBN = 978-0849316203
| pages = 17}}</ref>
<ref name="Oschmann_Schubert_1999_20">{{Citation
| title = Blow-Fill-Seal Technology
| author-link =
| last1 = Oschmann
| first1 = R.
| last2 = Schubert
| first2 = O. E.
| edition =
| publisher = Wissenschaftliche Verlagsgesellschaft mbH – CRC Press Inc.
| location = Stuttgart
| year = 1999
| volume = 40
| language = en
| ISBN = 978-0849316203
| pages = 21}}</ref>
<ref name="Oschmann_Schubert_1999_23">{{Citation
| title = Blow-Fill-Seal Technology
| author-link =
| last1 = Oschmann
| first1 = R.
| last2 = Schubert
| first2 = O. E.
| edition =
| publisher = Wissenschaftliche Verlagsgesellschaft mbH – CRC Press Inc.
| location = Stuttgart
| year = 1999
| volume = 40
| language = en
| ISBN = 978-0849316203
| pages = 23}}</ref>
<ref name="Oschmann_Schubert_1999_42">{{Citation
| title = Blow-Fill-Seal Technology
| author-link =
| last1 = Oschmann
| first1 = R.
| last2 = Schubert
| first2 = O. E.
| edition =
| publisher = Wissenschaftliche Verlagsgesellschaft mbH – CRC Press Inc.
| location = Stuttgart
| year = 1999
| volume = 40
| language = en
| ISBN = 978-0849316203
| pages = 42}}</ref>
<ref name="Oschmann_Schubert_1999_81">{{Citation
| title = Blow-Fill-Seal Technology
| author-link =
| last1 = Oschmann
| first1 = R.
| last2 = Schubert
| first2 = O. E.
| edition =
| publisher = Wissenschaftliche Verlagsgesellschaft mbH – CRC Press Inc.
| location = Stuttgart
| year = 1999
| volume = 40
| language = en
| ISBN = 978-0849316203
| pages = 81}}</ref>
<ref name="Downey_2016">
{{Citation
| title = The Manufacture of Sterile Pharmaceuticals and Liquid Medical Devices Using Blow-Fill-Seal Technology · Points to Consider
| author-link =
| last1 = Downey
| first1 = K.
| last2 = Haerer
| first2 = M.
| last3 = Marguillier
| first3 = S.
| last4 = Åkerman
| first4 = P.
| edition = 1st
| publisher = Editio-Cantor-Verlag
| location =
| year = 2016
| volume =
| language = en
| ISBN = 9783871934438
| pages = 64}}</ref>


<ref name="EPN_1989">European Plastics News. (1989). United Kingdom: IPC Press. p. 14</ref>
Blow-fill-seal technology reduces personnel intervention making it a more robust method for the aseptic preparation of sterile pharmaceuticals. BFS is used for the filling of vials for [[wikt:parenteral|parenteral]] preparations and infusions, [[eye drops]], and [[inhalation]] products. Generally the plastic containers are made up of [[polyethylene]] and [[polypropylene]]. Polypropylene is more commonly used to form containers which are further sterilised by [[autoclaving]] as polypropylene has greater thermostability.


</references>
==See also==
*[[Blow molding]]

==References==
<references />
* Soroka, W, "Fundamentals of Packaging Technology", IoPP, 2002, {{ISBN|1-930268-25-4}}
* Yam, K. L., "Encyclopedia of Packaging Technology", John Wiley & Sons, 2009, {{ISBN|978-0-470-08704-6}}

==External links==
* Blow-Fill-Seal Technology, slide presentation [https://www.slideshare.net/SudheerNunna/blowfill-technology]


{{packaging}}
{{packaging}}
Line 58: Line 544:
[[Category:Food industry]]
[[Category:Food industry]]
[[Category:Pharmaceutical industry]]
[[Category:Pharmaceutical industry]]

{{engineering-stub}}

Revision as of 13:16, 24 February 2022

BFS-packaged eye drops for single use

Blow-Fill Seal, also spelled as Blow/Fill/Seal, in this article abbreviated as BFS, is an automated manufacturing process by which plastic containers, such as bottles or ampoules are, in a continuous operation, blow-formed, filled, and sealed.[1][2] It takes place in a sterile, enclosed area inside a machine, without human intervention, and thus can be used to aseptically manufacture sterile pharmaceutical or non-pharamceutical liquid/semiliquid unit-dosage forms.[3][4] BFS is an advanced aseptic processing technology that is typically used for filling and packaging of certain sterile liquid formulations like liquid ophtalmics, inhalational anesthetics, or lavaging agents, but can also be used for injectables,[1] parenterals,[5] and several other liquid or semiliquid medications,[6] with fill volumes ranging from 0.1...1000 cm³.[7][8][9] Compared against traditional glass ampoules, BFS ampoules are inexpensive, lightweight, and shatterproof.[10] Important BFS system suppliers are Weiler Engineering, Rommelag (Bottelpack),[11] and Brevetti Angela.

History

BFS was developed in the early 1960s[12] at Rommelag.[13] In 1963, Gerhard Hansen applied for a patent on the BFS process.[14] Originally, it was used for packaging of non-sterile products, such as non-sterile medical devices, food, and cosmetics.[10] In the early 1970s, Rommelag's Bottelpack system was first used for packing large volume pharmaceutical solutions.[13] By the late 1980s, BFS had been well-established in the packaging industry, especially for packaging pharmaceutical and healthcare products.[15] During the 1980s and 1990s, BFS came into use for the now common small volume unit-dosage forms.[13] Since the early 2000s, BFS has been emerging as the preferred packaging process for parenteral products.[7]

BFS process

The BFS process functions similarly to conventional extrusion blow molding, and takes place within a BFS machine.[6] First, a plastic polymer resin is heated to >160 °C and compressed to 35 MPa,[12][16] allowing it to be extruded in tubular form,[1] and be taken over by an open two-part[17] mold to form the container. Then, the mold closes which welds the bottom of the container. Simultaneously, the parison above the mold is cut, or the filling needles are placed in the parison head without the parison being cut (rotary BFS type). Next, a filling mandrel with blowing air function is placed in the neck area that seals the container. Sterile compressed air is then introduced through the filling mandrel to inflate and form the container. In the BFS process for smaller ampoules the compressed air system is avoided by using vacuum forming the container instead. After the BFS container has been formed, the desired liquid is filled into the container through the filling mandrel unit. Then, the filling mandrel unit is lifted off, and the head mold hermetically seals the container. Simultaneously, the head contour is formed by vacuum. In the last step, the mold opens and the finished container leaves the mold.[6]

One process cycle takes a few seconds.[12] The process speed and thus process output largely depends upon the BFS container size and the BFS machinery dimensioning. For instance, in the early 2000s, Rommelag's 3012, 305, and 4010 M machines had outputs of approximately 4000, 8000, or 20,000 containers per hour.[11] These machines have been succeeded by the Rommelag 312, 321, 360, 364 and 460 machines with output ranges of up to 35,000 containers per hour.

Sterility requirements

The BFS processes is an aseptic filling process, which produces sterile products and thus needs to be sterile.[18] Aseptic BFS machines must be designed in a way that prevents extraneous contamination.[19] Thus, rotary-type BFS machines are placed in classified areas same as shuttle-type BFS machines (open parison), which have a cleanroom shroud grade-A-compliant provided with sterilised air and kept under overpressure. Automatic SIP programs are used to sterilise the BFS equipment and this avoids human interventions. Due to automatic start up and filling processes BFS machines require no human interaction during the actual BFS process. However, certain adjustments or interventions need to be carried out by personnel. Both particle and microbiological contamination monitoring are required in a BFS machine environment, as well as routine CIP/SIP processes.[20] BFS machines are typically fitted with several different sterilising air filtration systems for the buffer air, support parison air and air shroud grade A air (if needed for shuttle machines, e. g. open parison type ones).[9] Typically, the air is sterilised by filtration systems that have automatic filter integrity testing installed (i. e. automatic water intrusion or particle testing). The air systems are typically integrated into the SIP cycle of the BFS machine. [21]

BFS material

The materials used in BFS packaging are usually polyolefins, mainly polyethylene (LDPE[22][23] or HDPE),[24] and polypropylene (PP).[25][26][27] These materials are robust and inert to ensure sterility and tightness during the product's shelf life.[5] Diffusion tendencies can be reduced by using virgin polymers, but diffusion cannot be prevented entirely. This is due to the nature of polyolefins and their additives, if present.[25] Several polyethylene suppliers have developed special EP or USP grade resin for BFS containers. Permeation into BFS containers and water loss may be an issue with some BFS resin. Therefore, in some applications, secondary packaging methods (laminate pouches) are used.[28]

Advantages

BFS allows many different container designs, a consistent high process quality, a high process output,[7] and is, compared against other packaging processes, inexpensive.[26] In addition to that, BFS containers are lighter than glass containers, and shatterproof, which eases their transport.[10][29] Due to the single-dose nature of BFS containers, they are more convenient to use for patients.[30] BFS technology assures high levels of sterility,[31][32][33] especially compared against conventional filling,[34] which is mainly achieved by the absence of human contact/interventions – a major source of contamination.[35]

External links

References

  1. ^ a b c Niazi, Sarfaraz K. (2020), Handbook of Pharmaceutical Manufacturing Formulations – Volume 6: Sterile Products (3rd ed.), Boca Raton London New York: CRC Press, ISBN 978-1-138-10383-2, p. 33
  2. ^ Steinborn, Leonhard (2005), GMP/ISO Quality Audit Manual for Healthcare Manufacturers and Their Suppliers – Volume 2: Regulations, Standards, and Guidelines (6th ed.), Boca Raton London New York Washington, D.C.: CRC Press, ISBN 0-8493-1847-5, p. 261
  3. ^ Sinclair, C S (1995). "Performance of blow/fill/seal equipment under controlled airborne microbial challenges" (PDF). PDA-Journal of Pharmaceutical Science and Technology. 49: 494–499. Retrieved 24 March 2021.
  4. ^ Bradley, A (July 1991), "Airborne microbial challenges of blow/fill/seal equipment: A case study" (PDF), Journal of Parenteral Science and Technology, 45 (4): 187–194, retrieved 25 March 2021
  5. ^ a b Flickinger, Michael C. (2013), Downstream Industrial Biotechnology – Recovery and Purification, Hoboken: Wiley, ISBN 978-1-118-13124-4, p. 703
  6. ^ a b c Thielen, Michael (2021), Extrusion Blow Molding, Carl Hanser Verlag, ISBN 9781569908419, p. 139
  7. ^ a b c Gibson, Mark (2009), Pharmaceutical Preformulation and Formulation (2nd ed.), Newy York London: informa healthcare, ISBN 978-1-4200-7318-8, p. 339
  8. ^ Spalding, Mark A.; Chatterjee, Ananda M. (2018), Handbook of Industrial Polyethylene and Technology (1st ed.), Beverly: Scrivener Publishing, ISBN 9781119159766, p. 1103
  9. ^ a b Downey, K.; Haerer, M.; Marguillier, S.; Åkerman, P. (2016), The Manufacture of Sterile Pharmaceuticals and Liquid Medical Devices Using Blow-Fill-Seal Technology · Points to Consider (1st ed.), Editio-Cantor-Verlag, p. 64, ISBN 9783871934438
  10. ^ a b c Amin, A.; Chauhan, S.; Dare, M.; Bansal, A. K. (2012), Sorption of antimicrobial agents in blow-fill-seal packs, informa healthcare, doi:10.3109/10837450.2010.516438, ISSN 1083-7450
  11. ^ a b Dean, D. A.; Evans, E. R.; Hall, I. H. (2000), Pharmaceutical Packaging Technology, London New York: Taylor & Francis, ISBN 0-7484-0440-6, p. 438
  12. ^ a b c Swarbrick, James; Boylan, James C. (2001), Encyclopedia of Pharmaceutical Technology – Volume 20, New York · Basel: Marcel Dekker, ISBN 9780824728199, p. 1
  13. ^ a b c Oschmann, R.; Schubert, O. E. (1999), Blow-Fill-Seal Technology, vol. 40, Stuttgart: Wissenschaftliche Verlagsgesellschaft mbH – CRC Press Inc., p. 17, ISBN 978-0849316203
  14. ^ United Kingdom GB1041548A, Gerhard Hansen, "Improvements relating to blow moulding machines", published 1966-09-07 
  15. ^ European Plastics News. (1989). United Kingdom: IPC Press. p. 14
  16. ^ Oschmann, R.; Schubert, O. E. (1999), Blow-Fill-Seal Technology, vol. 40, Stuttgart: Wissenschaftliche Verlagsgesellschaft mbH – CRC Press Inc., p. 21, ISBN 978-0849316203
  17. ^ Rosato, Dominick V.; Rosato, Donald V.; Rosato, Matthew V. (2005), Plastic Product Material and Process Selection Handbook, Elsevier Science & Technology Books, ISBN 9780080514055, p. 302
  18. ^ Oschmann, R.; Schubert, O. E. (1999), Blow-Fill-Seal Technology, vol. 40, Stuttgart: Wissenschaftliche Verlagsgesellschaft mbH – CRC Press Inc., p. 23, ISBN 978-0849316203
  19. ^ Nema, Sandeep; Ludwig, John D. (2010), Pharmaceutical Dosage Forms: Parental Medications – Volume 3: Regulations, Validation and the Future (3rd ed.), New York, London: informa healthcare, p. 7
  20. ^ Swarbrick, James; Boylan, James C. (2001), Encyclopedia of Pharmaceutical Technology – Volume 20, New York · Basel: Marcel Dekker, ISBN 9780824728199, p. 2
  21. ^ Jornitz, Maik W. (2020), Filtration and Purification in the Biopharmaceutical Industry (3rd ed.), Boca Raton London New York: CRC Press, ISBN 978-1-138-05674-9, p. 539
  22. ^ Gad, Shayne Cox (2008), Pharmaceutical Manufacturing Handbook – Production and Processes, Hoboken: Wiley, ISBN 978-0-470-25958-0, p. 103
  23. ^ das Nevas, José; Sarmento, Bruno (2014), Mucosal Delivery of Biopharmaceuticals – Biology, Challenges and Strategies, New York Heidelberg Dordrecht London: Springer, ISBN 978-1-4614-9523-9, p. 444
  24. ^ Vasile, Cornelia; Pascu, Mihaela (2005), Practical Guide to Polyethylene, Shawbury: Rapra Technology Limited, ISBN 1-85957-493-9, p. 124
  25. ^ a b Amin, A.; Sangamwar, A.; Dare, M.; Bansal, A. K. (2012), Interaction of antimicrobial preservatives with blow-fill-seal packs: correlating sorption with solubility parameters, informa healthcare, doi:10.3109/10837450.2011.557733, ISSN 1083-7450
  26. ^ a b Denyer, Stephen P.; Hodges, Norman; Gorman, Sean P.; Gilmore, Brendan F. (2011), Hugo and Russell’s Pharmaceutical Microbiology, Chichester: Wiley-Blackwell, ISBN 9781444330632, p. 387
  27. ^ Oschmann, R.; Schubert, O. E. (1999), Blow-Fill-Seal Technology, vol. 40, Stuttgart: Wissenschaftliche Verlagsgesellschaft mbH – CRC Press Inc., p. 42, ISBN 978-0849316203
  28. ^ Spalding, Mark A.; Chatterjee, Ananda M. (2018), Handbook of Industrial Polyethylene and Technology (1st ed.), Beverly: Scrivener Publishing, ISBN 9781119159766, p. 1104
  29. ^ Oschmann, R.; Schubert, O. E. (1999), Blow-Fill-Seal Technology, vol. 40, Stuttgart: Wissenschaftliche Verlagsgesellschaft mbH – CRC Press Inc., p. 81, ISBN 978-0849316203
  30. ^ Pearlman, Rodney; Wang, Y. John (1996), Formulation, Characterization, and Stability of Protein Drugs – Case Histories; Volume 9 of Pharmaceutical Biotechnology, New York, Boston, Dordrecht, London, Moscow: kluwer Academic Publishers, ISBN 0-306-45332-0, p. 417
  31. ^ Groves, Michael J.; Murty, Ram (1995), Aseptic Pharmaceutical Manufacturing II – Applications for the 1990s, Boca Raton London New York: CRC Press, ISBN 978-0-935184-77-8, p. 364
  32. ^ Swarbrick, James; Boylan, James C. (2001), Encyclopedia of Pharmaceutical Technology – Volume 20, New York · Basel: Marcel Dekker, ISBN 9780824728199, p. 10
  33. ^ Gail, Lothar; Gommel, Udo (2018), Reinraumtechnik (in German) (4th ed.), Berlin: Springer, ISBN 978-3-662-54914-8, p. 602
  34. ^ Sandle, Tim (2016), Pharmaceutical Microbiology – Essentials for Quality Assurance and Quality Control, Cambridge: Woodhead Publishing Limited, ISBN 978-0-08-100022-9, p. 154
  35. ^ Hardee, Gregory E.; Baggot, J. Desmond (1998), Development and Formulation of Veterinary Dosage Forms – Drugs and the Pharmaceutical Sciences (2nd ed.), New York · Basel · Hong Kong: Marcel Dekker, ISBN 0824798783, p. 208

Cite error: A list-defined reference named "Nordhauser_1998_281" is not used in the content (see the help page).