Southampton BASIC System: Difference between revisions
Citation bot (talk | contribs) Add: s2cid, authors 1-1. Removed parameters. Some additions/deletions were parameter name changes. | Use this bot. Report bugs. | Suggested by Whoop whoop pull up | #UCB_webform 323/990 |
Added {{One source}} tag |
||
Line 1: | Line 1: | ||
{{One source|date=December 2023}} |
|||
{{see also|SOB (disambiguation)}} |
{{see also|SOB (disambiguation)}} |
||
{{Use dmy dates|date=August 2021}} |
{{Use dmy dates|date=August 2021}} |
Latest revision as of 17:13, 11 December 2023
This article relies largely or entirely on a single source. (December 2023) |
Southampton BASIC System (SOBS) was a dialect of the BASIC programming language developed for and used on ICT 1900 series computers in the late 1960s and early 1970s; it was implemented as an incremental BASIC interpreter under the MINIMOP operating system at the University of Southampton[1] and also ran under MAXIMOP.
It was operated from a Teletype terminal, though CRT terminals could also be used.
Language characteristics
[edit]In common with many early implementations of BASIC, SOBS needed lines to have line numbers, both to allow a user to add new lines to the program in the desired place and also as targets for GOTO
and GOSUB
statements. A RENUMBER
facility was available to allow for sections of the code to be renumbered, by default in increments of 10, to allow more space in the middle of a program.
Other than line numbers, all numeric values were represented internally as floating point.
Statements
[edit]The language had relatively few statements by comparison with modern programming languages:
Statement | Purpose |
---|---|
DATA
|
Stored data for READ ing into variables at runtime
|
DIM var(size)...
|
Dimension an array. One-, two- and three-dimensional arrays were supported. |
END
|
Halt execution of the program. |
FOR var=start TO end [STEP incr]
|
Perform a set of statements repeatedly for varying values of var |
GOSUB line
|
Call a subroutine at a given line number; flow would return to the next statement when a RETURN was executed.
|
GOTO line
|
Unconditional branch to a given line number. |
IF expr THEN line [ELSE line]
|
Conditionally branch. The THEN and ELSE parts could only give line numbers to go to.
|
INPUT var
|
Prompt the user for input data |
LET var=expr
|
Assign a value to a variable. Unlike many modern dialects of BASIC, LET was not an optional word.
|
NEXT var
|
Perform the next iteration of a FOR loop.
|
PRINT
|
Output to the Teletype |
READ var...
|
Read data from DATA statements into variables
|
REM
|
Short for REM ark, this allowed for a comment to be placed on a line
|
RESTORE [line]
|
Reset the READ pointer in order to re-read DATA
|
RETURN
|
Return to the line following a GOSUB .
|
Note in particular the lack of a WHILE
-like statement; FOR
was the only looping construct available to programmers.
Variables
[edit]Variable names for numeric values were either a single letter, or a single letter followed by a single numeric digit, thus allowing for 286 discreet variables in total. Strings were supported; variable names for them had the same restriction but were followed by a pound (£
) symbol.
Functions
[edit]A limited number of numeric functions were provided, all of which took one numeric parameter:
Function | Function() returned |
---|---|
SIN
|
|
COS
|
|
ATN
|
|
SQR
|
|
LOG
|
|
EXP
|
|
INT
|
The largest integer not greater than |
SGN
|
−1, 0, or 1, depending on whether was less than, equal to, or greater than zero |
ABS
|
if was negative, otherwise |
Support for strings was more limited, with only one function, LEN
, which returned the length of the string parameter. Sub-strings were supported with square brackets, so A£[2,3]
referred to the sub-string of the string A£
from the 2nd character to the 3rd character inclusive, so
10 LET A£ = "FOO"
20 PRINT A£[2,3]
would print OO
This syntax was also supported on the left-hand side of an assignment, so
10 LET A£ = "FOO"
20 LET A£[2,2] = "BAR"
30 PRINT A£
would print FBARO
Arrays
[edit]Support for handling arrays of data was relatively strong, with MAT
statements able to read an entire array from DATA
statements, and perform useful matrix operations such as matrix addition, matrix subtraction, matrix multiplication, and finding the inverse matrix for a square matrix.
Example:
10 DIM A(3,3)
20 MAT READ A
30 DATA 1,1,2,1,0,2,0,2,1
40 DIM B(3,3)
50 MAT READ B
60 DATA 0,0,1,0,1,0,1,0,0
70 DIM C(3,3),D(3,3)
80 MAT C=A*B
90 MAT D=INV(C)
100 MAT PRINT D,
A is read from the first DATA statement
|
|
B is read from the second DATA statement
|
|
C is calculated by multiplying A and B
|
|
D is calculated as the inverse of C
|
The output would be 2 2 1 1 -1 0 4 -3 -2
Debugging
[edit]This section needs expansion. You can help by adding to it. (May 2009) |
SOBS had primitive debugging capabilities, limited mostly to the TRACE
statement. TRACE ON
would cause the interpreter to print each line number as it was executed.
References
[edit]- ^ Rees, M.J.; Oppenheimer, A.W. (21 January 1977). "SOBS – an incremental BASIC system". Software: Practice and Experience. 7 (5). Wiley InterScience: 631–643. doi:10.1002/spe.4380070508. S2CID 33989728. Archived from the original on 5 January 2013. Retrieved 18 May 2009.