GE BWR
This article needs additional citations for verification. (January 2014) |
GE BWR (General Electric Boiling Water Reactor) | |
---|---|
Generation | Generation I (BWR-1) Generation II |
Reactor concept | Light water reactor (LWR) |
Reactor line | Boiling water reactor (BWR) |
Designed by | General Electric |
Manufactured by | General Electric |
Main parameters of the reactor core | |
Fuel (fissile material) | 235U/239Pu (LEU/MOX) |
Fuel state | Solid |
Neutron energy spectrum | Thermal |
Primary control method | Control rods |
Primary moderator | Light water |
Primary coolant | Liquid (water) |
Reactor usage | |
Primary use | Generation of electricity |
Power (thermal) | 180 MWth (BWR-1) 1500 MWth (BWR-2) 2400 MWth (BWR-3) 3000 MWth (BWR-4) 3400 MWth (BWR-6) 4800 MWth (ESBWR) |
Power (electric) | 460 MWe (BWR-3) 784 MWe (BWR-4) 1,100 MWe (BWR-5) |
General Electric's BWR product line of Boiling Water Reactors represents the designs of a large percent of the fission reactors around the world.
History
The progenitor of the BWR line was the 5MW Reactor at the Valiecitos Boiling-Water reactor in 1957.
- Elk River - 5x5 fuel rod bundle (ge bwr?)
- Lacrosse - 10x10 fuel rod bundle (ge bwr?)
- BWR Type 1: In 1955 GE developed this design into the 180MW Dresden 1(6x6,7x7) reactor, embodying GE's BWR/1 design. External or internal steam separation. GE would further develop this design with Big Rock Point(9x9, 11x11 12x12), and Humboldt Bay(6x6, 7x7), but sharing the BWR1 classification. These three experimental designs used fuel rod bundles in 6x6, 8x8, 9x9, 11x11, 12x12, but GE's 9x9 bundle later used in type 2-6 reactors is different from the one used in the Type 1 era.[1] An example of designs later classified as Generation I reactor Humboldt Bay and Dodewaard had natural circulation. Type 1 was the first design with internal steam separation. It also had an isolation condenser, and pressure suppression containment.[2]
- BWR Type 2: 1963[3] 500MW[4] Included a large direct cycle. 5 recirculation loops. This design, as well as types 3-6 would later be classed as Generation II reactors for their increased scale, and their design as commercially viable, profitable, long life reactors, designs that would become the foundation for the improved Generation III. Oyster Creek had a large direct cycle.[2]
- BWR Type 3: Introduced in 1965 800MW[4][dead link] (Dresden 2 & 3) Improved ECCS with spray and flood. First jet pump use (internal). 2 recirculation loops. Dresden 2 and Brown's Ferry had improved ECCS, spray and flood. They also had a reactor core isolation cooling system.[2]
- BWR Type 4: Introduced in 1966 1,100MW (Decatur Al) Increased power density 20%.
- BWR Type 5: Introduced in 1969 (Moscow OH) Improved ECCS valve flow control. Recirculation flow control valves.
- BWR Type 6: Introduced in 1972, 1,390MW transitioned from 7x7 to 8x8 fuel bundle with longer, thinner rods, improved compact jet pumps with higher circulation and increased capacity of the steam separators and dryers, added fuel bundles, and increased output, reduced fuel duty, improved eccs, introduced a solid-state nuclear system protection system and reduced the size of the control room. A 1.22GW electrical BWR6 has 177 control rods and 748 fuel assemblies for a total of 46,376 fuel rods. It had a gravity containment flooder, and they had options for a compact control room, and only Clinton took the solid state nuclear system protection system.[2]
- ABWR: Higher safety margins, no external recirculation loops, reactor internal pumps. It also has fine motion control rod drives.
- ESBWR: Passive safety, natural circulation (no loops or pumps), 1,600MW It has a gravity flooder, isolation condenser, and passive containment cooling.[2]
Fuel Rod Bundles
GE-2
- 7x7 fuel bundle.[1]
GE-3
- Improved 7x7 fuel bundle with 49 fuel rods, one of which is segmented.[1]
GE-4
- 8x8 fuel bundle with 63 fuel rods and 1 water rod.[1]
GE-5
- Retrofit 8x8 fuel bundle Prepressurized and Barrier fuel bundles containing 62 and two water rods.[1]
GE-6 & 7
- Prepressurized at 3ATM with helium with a Barrier
GE-8
- 8x8 fuel bundle with 58 to 62 fuel rods and 2-6 water rods.[1] Prepressurized at 5ATM with helium.
GE-9
Containment
Mark I
A drywell Containment building which resembles an inverted lightbulb above the wetwell which is a steel torus containing water.
Mark II
Described as an "over-under" configuration with the drywell forming a truncated cone on a concrete slab. Below is a cylindrical suppression chamber made of concrete rather than just sheet metal.
Mark III
The GE Mark III Containment is a single barrier pressure containment and multi-barrier fission containment system consisting of the containment vessel (pressure and fission barrier), the shield building, auxiliary building, and the fuel building, all of which are normally kept at negative pressure which prevents the egress of fission products.
- Reduced reactor height
- improved seismic response
- Lower pressure containment design
- improve pipe whip design
- combines the cheaper dry containment with low pressure suppression type containment
Advantage
- One advantage of the BWR design is improved load-following by virtue of control rod manipulation combined with changing the recirculation flow rate. The integration of the turbine pressure regulator and control system with the recirculation flow control system allows automatic power changes of up to 25% of rated power without altering control rod settings.
- Bottom entry bottom mounted control rods allow refueling without removal of the control rods and drives, while also allowing drive testing with an open vessel prior to fuel loading.
- BWR allow lower primary coolant flow than PWR.
- Jet pumps internal to the reactor vessel provide 2/3rds of the recirculation flow allowing the external recirculation flow loop to be small and compact compared to contemporary PWR designs.
- Under loss of coolant jet pumps provide 10% power similar to boilers
- BWR designs operate constantly at about half the primary system pressure of PWR designs while producing the same quantity and quality of steam in a compact system enabling a fast eccs.
- 1020PSI Reactor Pressure Vessel pressure, and 288C temperature for BWR versus 2240psi and 326C for PWR
- steam generated in reactor pressure vessel in BWR whereas it is generated in steam generator on a second loop in a PWR
- BWR allows for bulk boiling while PWR doesn't
See also
- Nuclear power
- Generation I reactor
- Generation II reactor
- Generation III reactor
- Nuclear safety in the U.S.
- Economics of new nuclear power plants
- Pressurized water reactor
- Reduced moderation water reactor
- Advanced Heavy Water Reactor
- Other Gen III+ designs
References
- ^ a b c d e f "Physical Characteristics of GE BWR Fuel Assemblies" (PDF). Web.ornl.gov. Retrieved 11 January 2014.
- ^ a b c d e http://www.powermag.com/the-evolution-of-the-esbwr/?printmode=1
- ^ "Boiling Water Reactor Basics" (PDF). Edf.com. Retrieved 11 January 2014.
- ^ a b "House Of Foust" (PDF). House Of Foust. Archived from the original (PDF) on October 29, 2013. Retrieved 2014-02-20.
{{cite web}}
: Unknown parameter|deadurl=
ignored (|url-status=
suggested) (help)